--MibName=raisecomSystem
-- =======================================================================
-- Version info 
--
-- Version 0.1 Created 2003.12.17 by GONGGUIDONG
-- This version of MIB is created just for the use of Network Management Systems
-- display the  memory and cpu.
--
-- Copyright(c) 2002-2005 by RAISECOM TECH, Ltd.     
-- modify history
-- 01, 20131012, huxiangfeng, Add two traps.
-- 01, 20090915, qiyun, Add CPU monitor MIBs.
--                   
-- =======================================================================



RAISECOM-SYSTEM-MIB DEFINITIONS ::= BEGIN

	IMPORTS
        MODULE-IDENTITY,Unsigned32 
                	FROM SNMPv2-SMI
        OBJECT-TYPE     
                    FROM SNMPv2-SMI
        raisecomAgent    
                    FROM RAISECOM-BASE-MIB
        TruthValue
                    FROM SNMPv2-TC 
        EnableVar	
                    FROM SWITCH-TC
        TimeStamp,TEXTUAL-CONVENTION
                    FROM SNMPv2-TC;

	raisecomSystem MODULE-IDENTITY
                LAST-UPDATED 	"200507270000Z"
                ORGANIZATION 	"RAISECOM TECH, Ltd."
                CONTACT-INFO 	"www.raisecom.com"
                DESCRIPTION  	
                		"raisecom System objects: objects common to all platforms."
        	::= { raisecomAgent 1 }	    
--       	
-- Textual Conventions
--
						
    ProcessStatus ::= TEXTUAL-CONVENTION
		STATUS	current
		DESCRIPTION
	   	    	"Status of the process."		
        SYNTAX   INTEGER
                {
	            r_running(1),
				d_interruptible_sleep(2),
				s_uninterruptible_sleep(3),
				t_stopped(4),
				z_zombie(5),
				x_dead(6),
				w_paging(7)
                }   
                      
    CPUTimeStamp ::= TEXTUAL-CONVENTION
        DISPLAY-HINT "4d.4d.4d.4d"
        STATUS       current
        DESCRIPTION                
                "The time in seconds that could represent signed
                quantities like time delay with respect to some
                source. The signed integer part is in the first 
                32 bits and the fraction part is in the last 32 bits."
        REFERENCE
                "D.L. Mills, 'Network Time Protocol (Version 3)',
                RFC-1305, March 1992, Sections 2,  3.2.1"
        SYNTAX     OCTET STRING (SIZE (16))


--
-- RAISECOM CPU objects
--   

	raisecomCpu MODULE-IDENTITY
                LAST-UPDATED 	"200412170000Z"
                ORGANIZATION 	"RAISECOM TECH, Ltd."
                CONTACT-INFO 	"www.raisecom.com"
                DESCRIPTION  	
                		"raisecom System objects: objects common to all platforms."
        	::= { raisecomSystem 1 } 
                   
--------------------------------------------------------------------------
--raisecomCPUTrapGroup
-------------------------------------------------------------------------- 
     raisecomCPUTrapGroup  OBJECT IDENTIFIER
                   ::= { raisecomCpu 1 }   
                   
     raisecomCPURisingThreshold NOTIFICATION-TYPE
	        OBJECTS { raisecomProcessIndex, raisecomProcessUtilization,raisecomCPUUtilizationCpuIdx, raisecomCPUUtilization }
	        STATUS  current
	        DESCRIPTION
	             "CPU utilization rising threshold trap transfer."
	        ::= { raisecomCPUTrapGroup 1 }
      	                   
	 raisecomCPURisingThresholdRecover NOTIFICATION-TYPE
	        OBJECTS {raisecomCPUUtilizationCpuIdx, raisecomCPUUtilization }
	        STATUS  current
	        DESCRIPTION
	             "CPU utilization rising threshold return to normal trap transfer."
	        ::= { raisecomCPUTrapGroup 2 }
	        		                   
--------------------------------------------------------------------------
--raisecomCPUScalarGroup
--------------------------------------------------------------------------   

       raisecomCPUScalarGroup  OBJECT IDENTIFIER
                   ::= { raisecomCpu 2 }

        raisecomCpuTotalProcNum OBJECT-TYPE
                   SYNTAX  INTEGER  (1..2000)
                   ACCESS  read-only
                   STATUS  current                     
                   DESCRIPTION
                          "Total number of processes."
                   ::= { raisecomCPUScalarGroup 1}  
  
                   
       raisecomCPUHistoryTableSize OBJECT-TYPE
                   SYNTAX  INTEGER                   
                   ACCESS  read-only
                   STATUS  current                  
                   DESCRIPTION
                          "A value configured by the user which specifies 
                          the number of reports in the history table."  
                   DEFVAL { 60 }
                   ::= { raisecomCPUScalarGroup 2} 
                   
       raisecomCPUThresholdTrapEnable OBJECT-TYPE
                   SYNTAX  EnableVar
                   ACCESS  read-write
                   STATUS  deprecated  
                   DESCRIPTION
                          "The administration status of the CPU utilization threshold trap."
                   ::= { raisecomCPUScalarGroup 3}   
                   
       raisecomCPURisingThresholdValue OBJECT-TYPE
                   SYNTAX  INTEGER  (2..99)
                   ACCESS  read-write
                   STATUS  current                    
                   DESCRIPTION
                          "The percentage rising threshold value configured by the user. 
                          The value indicates, if the CPU utilization which rise from 
                          raisecomCPUFallingThresholdValue is equal to or above this value 
                          for raisecomCPUThresholdInterval duration then send 
                          a raisecomCPURisingThreshold notification to the NMS." 
                   DEFVAL { 99 }
                   ::= { raisecomCPUScalarGroup 4} 
                   
       raisecomCPURecoverThresholdValue OBJECT-TYPE
                   SYNTAX  INTEGER  (0..98)
                   ACCESS  read-write
                   STATUS  current                     
                   DESCRIPTION
                          "The percentage falling threshold value configured by the user. 
                          The value indicates, if the CPU utilization which fell from 
                          raisecomCPURecoverThresholdValue is equal to or below this value 
                          for raisecomCPUThresholdInterval duration then send 
                          a raisecomCPUFallingThreshold notification to the NMS."
                   DEFVAL { 79 }
                   ::= { raisecomCPUScalarGroup 5}    
                   
       raisecomCPUThresholdInterval OBJECT-TYPE
                   SYNTAX  INTEGER  (5..36000)
                   ACCESS  read-write
                   STATUS  current                     
                   DESCRIPTION
                          "This is an observation interval.
                          The value of this object indicates that the CPU utilization 
                          should be above raisecomCPURisingThresholdValue for this 
                          duration to send a raisecomCPURisingThreshold notification 
                          to the NMS or below raisecomCPUFallingThresholdValue for 
                          this duration to send a raisecomCPUFallingThreshold."
                   DEFVAL { 60 }
                   ::= { raisecomCPUScalarGroup 6}  
                   
        raisecomCpuNum OBJECT-TYPE
                   SYNTAX  INTEGER  
                   ACCESS  read-only
                   STATUS  current                     
                   DESCRIPTION
                          "Total number of cpu."
                   ::= { raisecomCPUScalarGroup 7}     
                   
                         
--------------------------------------------------------------------------
--raisecomCPUTableGroup
--------------------------------------------------------------------------   

       raisecomCPUTableGroup  OBJECT IDENTIFIER
                   ::= { raisecomCpu 3 }

--------------------------------------------------------------------------
--raisecomCPUUtilizationGroup
--------------------------------------------------------------------------   

       raisecomCPUUtilizationGroup  OBJECT IDENTIFIER
                   ::= { raisecomCPUTableGroup 1 }

---------------------------------
--raisecomCPUUtilizationTable
---------------------------------
       raisecomCPUUtilizationTable OBJECT-TYPE
				   SYNTAX  SEQUENCE OF RaisecomCPUUtilizationEntry
				   ACCESS  not-accessible
				   STATUS  current
				   DESCRIPTION
				            "This table contains information about multi-core CPU utilization."
				   ::= { raisecomCPUUtilizationGroup 1 }                          
		
	   raisecomCPUUtilizationEntry OBJECT-TYPE
				    SYNTAX  RaisecomCPUUtilizationEntry
				    ACCESS  not-accessible
				    STATUS  current
				    DESCRIPTION
				            "Information about the CPU utilization."
				    INDEX           { raisecomCPUUtilizationPeriod,raisecomCPUUtilizationCpuIdx } 
				    ::= { raisecomCPUUtilizationTable 1 }
		
	   RaisecomCPUUtilizationEntry ::= SEQUENCE {
			        raisecomCPUUtilizationPeriod    INTEGER, 
			        raisecomCPUUtilizationCpuIdx    INTEGER,
			        raisecomCPUUtilization          INTEGER			
			        }  
			        					
	   raisecomCPUUtilizationPeriod OBJECT-TYPE
					SYNTAX	INTEGER {
										oneSec(1), 
										fiveSec(2), 
										oneMin(3),
										tenMin(4),
										twoHour(5)
									}				    
					ACCESS  not-accessible
					STATUS  current
					DESCRIPTION
					"Periods for computing CPU utilization."
					::= { raisecomCPUUtilizationEntry 1 } 
					    
	   raisecomCPUUtilizationCpuIdx OBJECT-TYPE
					SYNTAX INTEGER (0..16)
					MAX-ACCESS read-only
					STATUS current
					DESCRIPTION
						"The cpu core index"
					::= { raisecomCPUUtilizationEntry 2 }

				
       raisecomCPUUtilization OBJECT-TYPE
					SYNTAX  INTEGER
					UNITS	"percent" 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"CPU busy percentage in the last specified period."
					::= { raisecomCPUUtilizationEntry 3 } 
---------------------------------
--raisecomTotalCPUUtilizationTable 
--------------------------------- 

       raisecomTotalCPUUtilizationTable OBJECT-TYPE
					SYNTAX SEQUENCE OF RaisecomTotalCPUUtilizationEntry
					MAX-ACCESS not-accessible
					STATUS current
					DESCRIPTION
						"This table contains information about total CPU utilization."
					::= { raisecomCPUUtilizationGroup 2 }  
					
		raisecomTotalCPUUtilizationEntry OBJECT-TYPE
					SYNTAX RaisecomTotalCPUUtilizationEntry
					MAX-ACCESS not-accessible
					STATUS current
					DESCRIPTION
						"Description."
					INDEX { raisecomTotalCPUPeriod }
					::= { raisecomTotalCPUUtilizationTable 1 }   
					
		RaisecomTotalCPUUtilizationEntry ::= SEQUENCE {  
					raisecomTotalCPUPeriod          INTEGER,
			        raisecomTotalCPUUtilization     INTEGER			
			        }         
			        
		raisecomTotalCPUPeriod OBJECT-TYPE
					SYNTAX INTEGER  {
										oneSec(1), 
										fiveSec(2), 
										oneMin(3),
										tenMin(4),
										twoHour(5)
									}
					MAX-ACCESS not-accessible
					STATUS current
					DESCRIPTION
						"Periods for computing CPU utilization."
					::= { raisecomTotalCPUUtilizationEntry 1 }				

					
		raisecomTotalCPUUtilization OBJECT-TYPE
					SYNTAX INTEGER (0..10000)
					UNITS "percent"
					MAX-ACCESS read-only
					STATUS current
					DESCRIPTION
						"CPU busy percentage in the last specified period."
					::= { raisecomTotalCPUUtilizationEntry 2 }
		
			

---------------------------------
--raisecomCPUHistoryTable  
--------------------------------- 
       raisecomCPUHistoryTable OBJECT-TYPE
				   SYNTAX   SEQUENCE OF RaisecomCPUHistoryEntry
				   ACCESS   not-accessible
				   STATUS   current
				   DESCRIPTION
				            "This table contains CPU hsitory utilization records."
				   ::= { raisecomCPUUtilizationGroup 3} 
				   
       raisecomCPUHistoryEntry OBJECT-TYPE
				    SYNTAX  RaisecomCPUHistoryEntry
				    ACCESS  not-accessible
				    STATUS  current
				    DESCRIPTION
				            "CPU history utilization record."
				    INDEX           { raisecomCPUHistoryPeriod, raisecomCPUHistoryIndex,raisecomCPUHistoryCpuIdx } 
				    ::= { raisecomCPUHistoryTable 1 }  
				    
       RaisecomCPUHistoryEntry ::= SEQUENCE {
       				raisecomCPUHistoryPeriod     INTEGER,
			        raisecomCPUHistoryIndex      INTEGER,  
			        raisecomCPUHistoryCpuIdx     INTEGER,
			        raisecomCPUHistoryUtil  INTEGER			          		
			        } 

	   raisecomCPUHistoryPeriod OBJECT-TYPE
					SYNTAX	INTEGER {
										fiveSec(1), 
										oneMin(2),
										tenMin(3),
										twoHour(4)
									}				    
					ACCESS  not-accessible
					STATUS  current
					DESCRIPTION
					"Periods for computing CPU history utilization, the first index of CPU history utilization table."
					::= { raisecomCPUHistoryEntry 1 }     
	
	   raisecomCPUHistoryIndex OBJECT-TYPE
					SYNTAX	INTEGER 				    
					ACCESS  not-accessible
					STATUS  current
					DESCRIPTION
					"Process sequence number,the second index of CPU history utilization table."
					::= { raisecomCPUHistoryEntry 2 }

	   raisecomCPUHistoryCpuIdx OBJECT-TYPE
					SYNTAX INTEGER (0..16)
					MAX-ACCESS read-only
					STATUS current
					DESCRIPTION
						"The cpu core index"
					::= { raisecomCPUHistoryEntry 3 }
	
	   raisecomCPUHistoryUtil OBJECT-TYPE
					SYNTAX	INTEGER
					UNITS	"percent" 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"History record of CPU utilization in the specified period. "
					::= { raisecomCPUHistoryEntry 4 }
---------------------------------
--raisecomTotalCPUHistoryTable  
--------------------------------- 
       raisecomTotalCPUHistoryTable OBJECT-TYPE
				   SYNTAX   SEQUENCE OF RaisecomTotalCPUHistoryEntry
				   ACCESS   not-accessible
				   STATUS   current
				   DESCRIPTION
				            "This table contains CPU hsitory utilization records."
				   ::= { raisecomCPUUtilizationGroup 4} 
				   
       raisecomTotalCPUHistoryEntry OBJECT-TYPE
				    SYNTAX  RaisecomTotalCPUHistoryEntry
				    ACCESS  not-accessible
				    STATUS  current
				    DESCRIPTION
				            "CPU history utilization record."
				    INDEX           { raisecomTotalCPUHistoryPeriod, raisecomTotalCPUHistoryIndex } 
				    ::= { raisecomTotalCPUHistoryTable 1 }  
				    
       RaisecomTotalCPUHistoryEntry ::= SEQUENCE {
       				raisecomTotalCPUHistoryPeriod     INTEGER,
			        raisecomTotalCPUHistoryIndex      INTEGER,  
			        raisecomTotalCPUHistoryUtil  INTEGER
			        } 

	   raisecomTotalCPUHistoryPeriod OBJECT-TYPE
					SYNTAX	INTEGER {
										fiveSec(1), 
										oneMin(2),
										tenMin(3),
										twoHour(4)
									}				    
					ACCESS  not-accessible
					STATUS  current
					DESCRIPTION
					"Periods for computing CPU history utilization, the first index of CPU history utilization table."
					::= { raisecomTotalCPUHistoryEntry 1 }     
	
	   raisecomTotalCPUHistoryIndex OBJECT-TYPE
					SYNTAX	INTEGER 				    
					ACCESS  not-accessible
					STATUS  current
					DESCRIPTION
					"Process sequence number,the second index of CPU history utilization table."
					::= { raisecomTotalCPUHistoryEntry 2 }
	
	   raisecomTotalCPUHistoryUtil OBJECT-TYPE
					SYNTAX	INTEGER
					UNITS	"percent" 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"History record of CPU utilization in the specified period. "
					::= { raisecomTotalCPUHistoryEntry 3 }
	
--------------------------------------------------------------------------
--raisecomCPUProcessesGroup
--------------------------------------------------------------------------   

       raisecomCPUProcessesGroup  OBJECT IDENTIFIER
                   ::= { raisecomCPUTableGroup 2 }

---------------------------------
--raisecomProcessesTable 
--------------------------------- 
       raisecomProcessesTable OBJECT-TYPE
				   SYNTAX   SEQUENCE OF RaisecomProcessesEntry
				   ACCESS   not-accessible
				   STATUS   current
				   DESCRIPTION
				            "This table contains information about processes."
				   ::= { raisecomCPUProcessesGroup 1 } 
				   
       raisecomProcessesEntry OBJECT-TYPE
				    SYNTAX  RaisecomProcessesEntry
				    ACCESS  not-accessible
				    STATUS  current
				    DESCRIPTION
				            "Information about processes."
				    INDEX           { raisecomProcessIndex } 
				    ::= { raisecomProcessesTable 1 }  
				    
       RaisecomProcessesEntry ::= SEQUENCE {
			        raisecomProcessIndex            INTEGER,
			        raisecomProcessPID              INTEGER,
			        raisecomProcessName             OCTET STRING,
			        raisecomProcessRunTimeTotal     CPUTimeStamp,
			        raisecomProcessInvokedTotal	    INTEGER,
			        raisecomProcessTimeCreated      TimeStamp,
			        raisecomProcessCurrentPriority  INTEGER,
			        raisecomProcessStatus           ProcessStatus 		
			        } 
			         
       raisecomProcessIndex OBJECT-TYPE
					SYNTAX  INTEGER 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"This object index of processes table."
					::= { raisecomProcessesEntry 1 }  
        
       raisecomProcessPID OBJECT-TYPE
					SYNTAX  INTEGER 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"This object contains the process ID."
					::= { raisecomProcessesEntry 2 } 
					
	   raisecomProcessName OBJECT-TYPE
					SYNTAX  OCTET STRING (SIZE(1..32))  				    
					ACCESS  read-only					
					STATUS  current
					DESCRIPTION
					"The name associated with this process."
					::= { raisecomProcessesEntry 3 } 			
					
	   raisecomProcessRunTimeTotal OBJECT-TYPE
					SYNTAX  CPUTimeStamp  				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"The amount of time the process occupied, in microseconds."
					::= { raisecomProcessesEntry 4 } 
	
	   raisecomProcessInvokedTotal OBJECT-TYPE
					SYNTAX  INTEGER 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"The number of times since raisecomProcessTimeCreated 
					that the process has been invoked."
					::= { raisecomProcessesEntry 5 }
	
	   raisecomProcessTimeCreated OBJECT-TYPE
					SYNTAX  TimeStamp  				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"The time when the process was created. 
					The process sequence number and the time 
					when the process was created, uniquely identifies a process."
					::= { raisecomProcessesEntry 6 }
					
	   raisecomProcessCurrentPriority OBJECT-TYPE
					SYNTAX  INTEGER  				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"The current priority at which the process is running."
					::= { raisecomProcessesEntry 7 }			
					
	   raisecomProcessStatus OBJECT-TYPE
					SYNTAX  ProcessStatus  				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"The current status of the process."
					::= { raisecomProcessesEntry 8 }		
				
										
---------------------------------
--raisecomProcessStatisticsTable 
--------------------------------- 
       raisecomProcessStatisticsTable OBJECT-TYPE
				   SYNTAX   SEQUENCE OF RaisecomProcessStatisticsEntry
				   ACCESS   not-accessible
				   STATUS   current
				   DESCRIPTION
				            "This table contains statistics information for processes.
				            The first index is raisecomProcessIndex,
				            the second index is raisecomProcessStatisticsPeriod"
				   ::= { raisecomCPUProcessesGroup 2 } 
				   
       raisecomProcessStatisticsEntry OBJECT-TYPE
				    SYNTAX  RaisecomProcessStatisticsEntry
				    ACCESS  not-accessible
				    STATUS  current
				    DESCRIPTION
				            "Statistics information for processes."
				    INDEX           { raisecomProcessIndex, raisecomProcessStatisticsPeriod } 
				    ::= { raisecomProcessStatisticsTable 1 }  
				    
       RaisecomProcessStatisticsEntry ::= SEQUENCE {
			        raisecomProcessStatisticsPeriod    INTEGER,
			        raisecomProcessRunTime             CPUTimeStamp, 
			        raisecomProcessUtilization         INTEGER			          		
			        } 
							
	   raisecomProcessStatisticsPeriod OBJECT-TYPE
					SYNTAX	INTEGER {
										fiveSec(1),
							            oneMin(2),
										tenMin(3)									
									}  				    
					ACCESS  not-accessible
					STATUS  current
					DESCRIPTION
					"Periods for process statistics,
					the second index of process statistics table."
					::= { raisecomProcessStatisticsEntry 1 }				
	
	   raisecomProcessRunTime OBJECT-TYPE
					SYNTAX	CPUTimeStamp 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"Time of the process occupied in the specified period."
					::= { raisecomProcessStatisticsEntry 2 } 
		
	   raisecomProcessUtilization OBJECT-TYPE
					SYNTAX	INTEGER
					UNITS	"percent" 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"This object provides a general idea of how busy 
					a process caused the processor to be over a specified period."
					::= { raisecomProcessStatisticsEntry 3 }	
	
---------------------------------
--raisecomDeadProcessesTable  
--------------------------------- 
       raisecomDeadProcessesTable OBJECT-TYPE
				   SYNTAX   SEQUENCE OF RaisecomDeadProcessesEntry
				   ACCESS   not-accessible
				   STATUS   current
				   DESCRIPTION
				            "This table contains dead processes information."
				   ::= { raisecomCPUProcessesGroup 3 } 
				   
       raisecomDeadProcessesEntry OBJECT-TYPE
				    SYNTAX  RaisecomDeadProcessesEntry
				    ACCESS  not-accessible
				    STATUS  current
				    DESCRIPTION
				            "Dead processes information."
				    INDEX           { raisecomDeadProcessIndex } 
				    ::= { raisecomDeadProcessesTable 1 }  
				    
       RaisecomDeadProcessesEntry ::= SEQUENCE {
			        raisecomDeadProcessIndex        INTEGER,
			        raisecomDeadProcessName         OCTET STRING,
			        raisecomDeadProcessPriority     INTEGER,
			        raisecomDeadProcessTimeDelete   TimeStamp,
			        raisecomDeadProcessDeadTimes    INTEGER,
			        raisecomDeadProcessStatus       ProcessStatus			          		
			        } 
	
	   raisecomDeadProcessIndex OBJECT-TYPE
					SYNTAX	INTEGER 				    
					ACCESS  not-accessible
					STATUS  current
					DESCRIPTION
					"Process sequence number,the index of dead processes table."
					::= { raisecomDeadProcessesEntry 1 }
	
       raisecomDeadProcessName OBJECT-TYPE
					SYNTAX	OCTET STRING (SIZE(1..32)) 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"The name associated with this dead process."
					::= { raisecomDeadProcessesEntry 2 }

       raisecomDeadProcessPriority OBJECT-TYPE
					SYNTAX	INTEGER 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"The priority at which the dead process."
					::= { raisecomDeadProcessesEntry 3 }

    					
	   raisecomDeadProcessTimeDelete OBJECT-TYPE
					SYNTAX	TimeStamp 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"The time when the process was deleted."
					::= { raisecomDeadProcessesEntry 4}
					
	   raisecomDeadProcessDeadTimes OBJECT-TYPE
					SYNTAX	INTEGER 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"Times of the process dead."
					::= { raisecomDeadProcessesEntry 5 }    
					
	   raisecomDeadProcessStatus OBJECT-TYPE
					SYNTAX	ProcessStatus 				    
					ACCESS  read-only
					STATUS  current
					DESCRIPTION
					"The status of the dead process."
					::= { raisecomDeadProcessesEntry 6}
 					
--
-- RAISECOM END Pool objects
--
	
	raisecomEndPool MODULE-IDENTITY
                LAST-UPDATED 	"200412170000Z"
                ORGANIZATION 	"RAISECOM TECH, Ltd."
                CONTACT-INFO 	"www.raisecom.com"
                DESCRIPTION  	
                		"raisecom System objects: objects common to all platforms."
        	::= { raisecomSystem 2 }
		
	raisecomEndPoolTable OBJECT-TYPE
	        SYNTAX      SEQUENCE OF RaisecomEndPoolEntry
	        MAX-ACCESS  not-accessible
	        STATUS      current
	        DESCRIPTION
	                "A table of drivers Pool on a managed system."
	        ::= { raisecomEndPool 1 }
	
	raisecomEndPoolEntry OBJECT-TYPE
	        SYNTAX      RaisecomEndPoolEntry
	        MAX-ACCESS  not-accessible
	        STATUS      current
	        DESCRIPTION
	                "An entry in the END driver Pool monitoring table."
	        INDEX       { raisecomBasePort }
	        ::= { raisecomEndPoolTable 1 }
	
	RaisecomEndPoolEntry ::=
	        SEQUENCE {
	                raisecomBasePort       	INTEGER,
	                raisecomTotalEndPool 	INTEGER,
	                raisecomFreeEndPool	INTEGER
	        }
		
	
	raisecomBasePort OBJECT-TYPE
	        SYNTAX  INTEGER 
	        MAX-ACCESS  not-accessible
	        STATUS  current
	        DESCRIPTION
	                "The port number based 1 of the port for which this entry
	                contains bridge management information."
   		    ::= {  raisecomEndPoolEntry 1 }
	
	raisecomTotalEndPool OBJECT-TYPE
	        SYNTAX      INTEGER
	        MAX-ACCESS  read-only
	        STATUS      current
	        DESCRIPTION
	                "Indicates the number of mBlks pre-allocated for this END driver."
	        ::= { raisecomEndPoolEntry 2 }

	raisecomFreeEndPool OBJECT-TYPE
	        SYNTAX      INTEGER
	        MAX-ACCESS  read-only
	        STATUS      current
	        DESCRIPTION
	                "Indicates the number of mBlks available  in  this END driver pool."
	        ::= { raisecomEndPoolEntry 3 }    

--
-- RAISECOM Memory objects
--                
	 raisecomMemory MODULE-IDENTITY
                LAST-UPDATED 	"200412170000Z"
                ORGANIZATION 	"RAISECOM TECH, Ltd."
                CONTACT-INFO 	"www.raisecom.com"
                DESCRIPTION  	
                		"raisecom System objects: memory objects."	
      ::= { raisecomSystem 3 }      
               
--  ------------------------------------------------------------------------
-- raisecomMemoryTrapGroup
-- ------------------------------------------------------------------------
		-- 1.3.6.1.4.1.8886.1.1.3.1
		raisecomMemoryTrapGroup OBJECT IDENTIFIER ::= { raisecomMemory 1 }

		
		-- 1.3.6.1.4.1.8886.1.1.3.1.1
		raisecomMemoryTrap NOTIFICATION-TYPE
			OBJECTS { raisecomMemoryTotal, raisecomMemoryUtil, raisecomMemoryThrshd }
			STATUS current
			DESCRIPTION 
				"Trap transfer when memory utilization upon threshold."
			::= { raisecomMemoryTrapGroup 1 }

		
		-- 1.3.6.1.4.1.8886.1.1.3.1.2
		raisecomMemoryTrapRecover NOTIFICATION-TYPE
			OBJECTS { raisecomMemoryTotal, raisecomMemoryUtil,raisecomMemoryThrshdRecover }
			STATUS current
			DESCRIPTION 
				"Trap transfer when memory utilization upon thresholdrecover."
			::= { raisecomMemoryTrapGroup 2 }

		
--  ------------------------------------------------------------------------
-- raisecomMemoryScalarGroup
-- ------------------------------------------------------------------------
		-- 1.3.6.1.4.1.8886.1.1.3.2
		raisecomMemoryScalarGroup OBJECT IDENTIFIER ::= { raisecomMemory 2 }

		
		-- 1.3.6.1.4.1.8886.1.1.3.2.1
		raisecomMemoryTotal OBJECT-TYPE
			SYNTAX INTEGER
			UNITS "Byte"
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"The total memory of the system for this duration."
			::= { raisecomMemoryScalarGroup 1 }

		
		-- 1.3.6.1.4.1.8886.1.1.3.2.2
		raisecomMemoryAvailable OBJECT-TYPE
			SYNTAX INTEGER
			UNITS "Byte"
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"The available memory of the system for this duration."
			::= { raisecomMemoryScalarGroup 2 }

		
		-- 1.3.6.1.4.1.8886.1.1.3.2.3
		raisecomMemoryUtil OBJECT-TYPE
			SYNTAX OCTET STRING (SIZE (1..8))   
			UNITS "percent"
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"The current value of memory utilization for this duration."
			::= { raisecomMemoryScalarGroup 3 }

		
		-- 1.3.6.1.4.1.8886.1.1.3.2.4
		raisecomMemoryTrapEnable OBJECT-TYPE
			SYNTAX EnableVar
			MAX-ACCESS read-write
			STATUS deprecated
			DESCRIPTION
				"The switch of memory trap."
			::= { raisecomMemoryScalarGroup 4 }

		
		-- 1.3.6.1.4.1.8886.1.1.3.2.5
		raisecomMemoryThrshd OBJECT-TYPE
			SYNTAX INTEGER    
			UNITS "percent"
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The threshold of memory monitor."
			::= { raisecomMemoryScalarGroup 5 }

		
		-- 1.3.6.1.4.1.8886.1.1.3.2.6
		raisecomMemoryThrshdRecover OBJECT-TYPE
			SYNTAX INTEGER   
			UNITS "percent"
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The recover threshold of memory monitor."
			::= { raisecomMemoryScalarGroup 6 }

		
		-- 1.3.6.1.4.1.8886.1.1.3.2.7
		raisecomMemoryMonInterval OBJECT-TYPE
			SYNTAX INTEGER   
			UNITS "second"
			MAX-ACCESS read-write
			STATUS current
			DESCRIPTION
				"The timer interval of memory monitor."
			::= { raisecomMemoryScalarGroup 7 }

		
		-- 1.3.6.1.4.1.8886.1.1.4.1
		raisecomDeviceType OBJECT-TYPE
			SYNTAX OCTET STRING
			MAX-ACCESS read-only
			STATUS current
			DESCRIPTION
				"Device type."
			::= { raisecomInformation 1 }
	
--
-- RAISECOM Information objects
--                


		 raisecomInformation MODULE-IDENTITY
                LAST-UPDATED 	"200507270000Z"
                ORGANIZATION 	"RAISECOM TECH, Ltd."
                CONTACT-INFO 	"www.raisecom.com"
                DESCRIPTION  	
                		"raisecom System objects: objects common to all platforms."
 		   		::= { raisecomSystem 4 }

		PortAlarmEventList ::= TEXTUAL-CONVENTION
		    STATUS current
		    DESCRIPTION
		        "The low three bits of An OCTET STRING represents an alarm 
		        events enabled or existed list on a port, in which each bit 
		        represents an alarm event type. the other bits of An OCTET
		         STRING are not used. The figure shown below illustrates the 
		         format of an alarm list.
		         
					         7 6 5 4 3 2 1 0
					        +-+-+-+-+-+-+-+-+
					        |               |
					        +-+-+-+-+-+-+-+-+
					         | | | | | | | |
					         | | | | | | | +- none
					         | | | | | | +--- none
					         | | | | | +----- none
					         | | | | +------- none
					         | | | +--------- none
					         | | +----------- not-forwarding
					         | +------------- link-fault
					         +--------------- link-down             
			
			The link-down bit set 1 represents that link-down event alarm output 
			is enabled on port, OR the link-down bit set 1 represents that link-down
			event occured on port. 
			The bit represents alarm output enabled in mibs:
													raisecomAlarmPortSyslogEvList
													raisecomAlarmPortNotifiesEvList  
													raisecomAlarmPortRelayEvList
			The bit represents alarm occured in mibs: raisecomAlarmPortEvList ."
		    SYNTAX OCTET STRING (SIZE (1))

 
		    raisecomDeviceType OBJECT-TYPE
		            SYNTAX  OCTET STRING
		           	MAX-ACCESS read-only
		            STATUS current
		            DESCRIPTION
		                  "Device type."
					::= { raisecomInformation 1 }   
					 
			--Temperature group	
		    raisecomTemperature    OBJECT IDENTIFIER ::= { raisecomInformation 2 }
		    
		       raisecomTemperatureValue OBJECT-TYPE
		               SYNTAX      INTEGER 
		               UNITS  	   "Celsius "
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The current temperature of the device."
        		  	   ::= { raisecomTemperature 1 }   
        		  	   
        	   raisecomTemperatureMin OBJECT-TYPE
       	               SYNTAX      INTEGER 
       	               UNITS  	   "Celsius "
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The minimum temperature that has occured."
        		  	   ::= { raisecomTemperature 2 }   
        	   
        	   raisecomTemperatureMax OBJECT-TYPE
       	               SYNTAX      INTEGER  
       	               UNITS  	   "Celsius "
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The maximum temperature that has occured."
        		  	   ::= { raisecomTemperature 3 }   
                                        
               raisecomTemperatureTrapEnable   OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     deprecated
                       DESCRIPTION 
                            " Indicates whether the temperature trap is enabled."                                   
 	                   ::= { raisecomTemperature 4 }
 	   
               raisecomTemperatureThresholdLow  OBJECT-TYPE
       	               SYNTAX      Integer32
       	               UNITS  	   "Celsius " 
                       MAX-ACCESS  read-write
                       STATUS      current
                       DESCRIPTION  
                       		"Low threshold of the temperature alarm."
        		  	   ::= { raisecomTemperature 5 }    

               raisecomTemperatureThresholdHigh  OBJECT-TYPE
       	               SYNTAX      Integer32   
       	               UNITS  	   "Celsius "
                       MAX-ACCESS  read-write
                       STATUS      current
                       DESCRIPTION  
                       		"High threshold of the temperature alarm."
        		  	   ::= { raisecomTemperature 6 }     
        		  	   
        	   raisecomTemperatureTrapTimes   OBJECT-TYPE
		               SYNTAX      INTEGER
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"How many times abnormal temperature has occured."
        		  	   ::= { raisecomTemperature 7 }

        	   raisecomTemperatureHighTimes   OBJECT-TYPE
		               SYNTAX      INTEGER
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"How many times high temperature has occured."
        		  	   ::= { raisecomTemperature 8 }

        	   raisecomTemperatureLowTimes   OBJECT-TYPE
		               SYNTAX      INTEGER
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"How many times low temperature has occured."
        		  	   ::= { raisecomTemperature 9 }
        	
        	--Vlot  Information
        	raisecomVolt    OBJECT IDENTIFIER ::= { raisecomInformation 3 }
        		  	   
        	raisecomVoltTable OBJECT-TYPE
					SYNTAX		SEQUENCE OF	RaisecomVoltEntry
					MAX-ACCESS	not-accessible
					STATUS		current
					DESCRIPTION
						 "A table of device vlot and associated properties.."
					::=	{  raisecomVolt 1 } 
				
				raisecomVoltEntry  OBJECT-TYPE
						SYNTAX		RaisecomVoltEntry
						MAX-ACCESS	not-accessible
						STATUS		current
						DESCRIPTION
						   	"Table entry for device vlot."
						INDEX {	raisecomVoltIndex }
						::=	{ raisecomVoltTable 1 } 	  
						            
			    RaisecomVoltEntry ::= SEQUENCE {
			        raisecomVoltIndex         	INTEGER,
			        raisecomVoltReference     	INTEGER,
			        raisecomVoltValue      	  	INTEGER,
			        raisecomVoltMin    		  	INTEGER,
			        raisecomVoltMax           	INTEGER,
			        raisecomVoltTrapEnable    	EnableVar,
			        raisecomVoltThresholdLow    Integer32,
			        raisecomVoltThresholdHigh   Integer32,
			        raisecomVoltTrapTimes       INTEGER,
			        raisecomVoltHighTimes       INTEGER,
			        raisecomVoltLowTimes        INTEGER
				    }
				
			    raisecomVoltIndex OBJECT-TYPE
						SYNTAX		INTEGER
						MAX-ACCESS	read-only
						STATUS		current
						DESCRIPTION
							"An index based 1 that uniquely identifies a volt entry."
						::=	{ raisecomVoltEntry 1 }
				
				raisecomVoltReference OBJECT-TYPE
		               SYNTAX      INTEGER   
		               UNITS  	   "mV"
                       MAX-ACCESS  read-only
                       STATUS      current    
                       DESCRIPTION  
                       		"The reference volt."
        		  	   ::= { raisecomVoltEntry 2 }    
        		  	   
        		raisecomVoltValue   OBJECT-TYPE
		               SYNTAX      INTEGER
		               UNITS  	   "mV" 
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The current value."
        		  	   ::= { raisecomVoltEntry 3 } 
        		  	   
        		raisecomVoltMin     OBJECT-TYPE
		               SYNTAX      INTEGER
		               UNITS  	   "mV" 
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The minimum value that has occured."
        		  	   ::= { raisecomVoltEntry 4 }
				
                raisecomVoltMax    OBJECT-TYPE
		               SYNTAX      INTEGER
		               UNITS  	   "mV" 
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The maximum value that has occured."
        		  	   ::= { raisecomVoltEntry 5 }    
        		 
        		raisecomVoltTrapEnable  OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     deprecated
                       DESCRIPTION 
                            " Indicates whether the volt trap is enabled."                                   
 	                   ::= { raisecomVoltEntry 6 }   
 	                   
 	            raisecomVoltThresholdLow  OBJECT-TYPE
       	               SYNTAX      Integer32
       	               UNITS  	   "mV" 
                       MAX-ACCESS  read-write
                       STATUS      current
                       DESCRIPTION  
                       		"The low threshold of the volt alarm."
        		  	   ::= { raisecomVoltEntry 7 } 

               raisecomVoltThresholdHigh  OBJECT-TYPE
       	               SYNTAX      Integer32
       	               UNITS  	   "mV" 
                       MAX-ACCESS  read-write
                       STATUS      current
                       DESCRIPTION  
                       		"The high threshold of the volt alarm."
        		  	   ::= { raisecomVoltEntry 8 }

                raisecomVoltTrapTimes   OBJECT-TYPE
		               SYNTAX      INTEGER
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"How many times abnormal volt has occured."
        		  	   ::= { raisecomVoltEntry 9 }

                raisecomVoltHighTimes   OBJECT-TYPE
		               SYNTAX      INTEGER
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"How many times high volt has occured."
        		  	   ::= { raisecomVoltEntry 10 }

                raisecomVoltLowTimes   OBJECT-TYPE
		               SYNTAX      INTEGER
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"How many times low volt has occured."
        		  	   ::= { raisecomVoltEntry 11 }
          	
          	--Device information trap  
        	raisecomInformationTrap    OBJECT IDENTIFIER ::= { raisecomInformation 4 } 
        	
        		 temperatureAbnormalTrap    NOTIFICATION-TYPE
				         OBJECTS { raisecomTemperatureValue }
				         STATUS  deprecated
				         DESCRIPTION
				               "Current temperature of the device is abnormal."
       					 ::= { raisecomInformationTrap 1 }
                 
                 temperatureNormalTrap    NOTIFICATION-TYPE
				         OBJECTS { raisecomTemperatureValue }
				         STATUS  deprecated
				         DESCRIPTION
				               "Current temperature of the device return to normal."
       					 ::= { raisecomInformationTrap 2 }
                 
                 raisecomVoltAbnormalTrap    NOTIFICATION-TYPE
				         OBJECTS { raisecomVoltIndex, raisecomVoltReference, raisecomVoltValue }
				         STATUS  deprecated
				         DESCRIPTION
				               "Current volt of the device is abnormal."
       					 ::= { raisecomInformationTrap 3 }

                 raisecomVoltNormalTrap    NOTIFICATION-TYPE
				         OBJECTS { raisecomVoltIndex, raisecomVoltReference, raisecomVoltValue }
				         STATUS  deprecated
				         DESCRIPTION
				               "Current volt of the device return to normal."
       					 ::= { raisecomInformationTrap 4 }

		--raisecomAlarm group	
		    raisecomAlarm    OBJECT IDENTIFIER ::= { raisecomInformation 7 }

          	--raisecomAlarmTrap trap  
        	raisecomAlarmTrap    OBJECT IDENTIFIER ::= { raisecomAlarm 1 } 
        	
        		 raisecomAlarmInformationTrap    NOTIFICATION-TYPE
				         OBJECTS { raisecomAlarmHistSource, raisecomAlarmHistDescr, raisecomAlarmHistTimestamp, raisecomAlarmHistType, raisecomAlarmHistStatus }
				         STATUS  current
				         DESCRIPTION
				               "Trap transfer alarm information in the alarm history table."				               
       					 ::= { raisecomAlarmTrap 1 }    
       					 
			--raisecomAlarmGlobal group	
		    raisecomAlarmGlobal    OBJECT IDENTIFIER ::= { raisecomAlarm 2 }
		    
		       raisecomAlarmTrapEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the global alarm trap is enabled."     
                       DEFVAL { disable}                              
 	                   ::= { raisecomAlarmGlobal 1 }
		    
		       raisecomAlarmSyslogEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the global alarm syslog is enabled."       
                       DEFVAL { disable}                            
 	                   ::= { raisecomAlarmGlobal 2 }

		       raisecomAlarmClear OBJECT-TYPE
 	                   SYNTAX     TruthValue
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            "This object instructs the management entity to clear the whole current alarm information."                                   
 	                   ::= { raisecomAlarmGlobal 3 }

			--raisecomAlarmPower group	
		    raisecomAlarmPower    OBJECT IDENTIFIER ::= { raisecomAlarm 3 }
		    
		       raisecomAlarmPowerTrapEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the power alarm trap is enabled." 
                       DEFVAL { enable}                                  
 	                   ::= { raisecomAlarmPower 1 }
		    
 		       raisecomAlarmPowerRelayEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the power alarm relay is enabled."                                   
                       DEFVAL { enable}                                  
 	                   ::= { raisecomAlarmPower 2 }

		       raisecomAlarmPowerSyslogEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the power alarm syslog is enabled."                                   
                       DEFVAL { enable}                                  
 	                   ::= { raisecomAlarmPower 3 }

        	   raisecomAlarmPowerOneTimes   OBJECT-TYPE
		               SYNTAX      INTEGER
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"How many times power one alarm has occured."
        		  	   ::= { raisecomAlarmPower 4 }   

        	   raisecomAlarmPowerTwoTimes   OBJECT-TYPE
		               SYNTAX      INTEGER
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"How many times power two alarm has occured."
        		  	   ::= { raisecomAlarmPower 5 }   
        		  	   
				raisecomAlarmPowerStatus OBJECT-TYPE
		               SYNTAX INTEGER { 
		                           dual_power_on(1),
		                           dual_power_off(2),
		                           power1_off(3),
		                           power2_off(4)
		                           }  
                       MAX-ACCESS  read-only
                       STATUS      current    
                       DESCRIPTION  
                       		"The status of power alarm."
        		  	   ::= { raisecomAlarmPower 6 } 

			--raisecomAlarmTemperature group	
		    raisecomAlarmTemperature    OBJECT IDENTIFIER ::= { raisecomAlarm 4 }
		    
		       raisecomAlarmTemperatureTrapEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the temperature alarm trap is enabled." 
                       DEFVAL { enable}                                  
 	                   ::= { raisecomAlarmTemperature 1 }
		    
		       raisecomAlarmTemperatureRelayEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the temperature alarm relay is enabled."                                   
                       DEFVAL { enable}                                  
 	                   ::= { raisecomAlarmTemperature 2 }

 		       raisecomAlarmTemperatureSyslogEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the temperature alarm syslog is enabled."                                   
                       DEFVAL { enable}                                  
 	                   ::= { raisecomAlarmTemperature 3 }

			--raisecomAlarmVolt group	
		    raisecomAlarmVoltage    OBJECT IDENTIFIER ::= { raisecomAlarm 5 }
		    
		       raisecomAlarmVoltTrapEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the volt alarm trap is enabled." 
                       DEFVAL { enable}                                  
 	                   ::= { raisecomAlarmVoltage 1 }
		    
		       raisecomAlarmVoltRelayEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the volt alarm relay is enabled."                                   
                       DEFVAL { enable}                                  
 	                   ::= { raisecomAlarmVoltage 2 }

 		       raisecomAlarmVoltSyslogEnable OBJECT-TYPE
 	                   SYNTAX     EnableVar
        			   MAX-ACCESS read-write
                       STATUS     current
                       DESCRIPTION 
                            " Indicates whether the volt alarm syslog is enabled."                                   
                       DEFVAL { enable}                                  
 	                   ::= { raisecomAlarmVoltage 3 }

        	--port fault alarm
        	raisecomAlarmPort     OBJECT IDENTIFIER ::= { raisecomAlarm 6 }
        		  	   
        	raisecomAlarmPortTable OBJECT-TYPE
					SYNTAX		SEQUENCE OF	RaisecomAlarmPortEntry
					MAX-ACCESS	not-accessible
					STATUS		current
					DESCRIPTION
						 "A table of port alarm information.."
					::=	{  raisecomAlarmPort 1 } 
				
				raisecomAlarmPortEntry  OBJECT-TYPE
						SYNTAX		RaisecomAlarmPortEntry
						MAX-ACCESS	not-accessible
						STATUS		current
						DESCRIPTION
						   	"Table entry for port alarm information."
						INDEX {	raisecomAlarmPortIndex }
						::=	{ raisecomAlarmPortTable 1 } 	  
						            
			    RaisecomAlarmPortEntry ::= SEQUENCE {
			        raisecomAlarmPortIndex         	 INTEGER,
			        raisecomAlarmPortSyslogEvList    PortAlarmEventList,
			        raisecomAlarmPortNotifiesEvList  PortAlarmEventList,
			        raisecomAlarmPortRelayEvList     PortAlarmEventList,
			        raisecomAlarmPortEvList          PortAlarmEventList
				    }
				
			    raisecomAlarmPortIndex OBJECT-TYPE
						SYNTAX		INTEGER
						MAX-ACCESS	not-accessible
						STATUS		current
						DESCRIPTION
							"This object index of alarm port entry."
						::=	{ raisecomAlarmPortEntry 1 }
				
				raisecomAlarmPortSyslogEvList OBJECT-TYPE
		               SYNTAX 	   PortAlarmEventList 
                       MAX-ACCESS  read-write
                       STATUS      current    
                       DESCRIPTION  
                       		"The port alarm event list of syslog enable status."
        		  	   ::= { raisecomAlarmPortEntry 2 } 

				raisecomAlarmPortNotifiesEvList OBJECT-TYPE
		               SYNTAX 	   PortAlarmEventList 
                       MAX-ACCESS  read-write
                       STATUS      current    
                       DESCRIPTION  
                       		"The port alarm event list of notifies enable status."
        		  	   ::= { raisecomAlarmPortEntry 3 } 

				raisecomAlarmPortRelayEvList OBJECT-TYPE
		               SYNTAX 	   PortAlarmEventList 
                       MAX-ACCESS  read-write
                       STATUS      current    
                       DESCRIPTION  
                       		"The port alarm event list of relay enable status."
        		  	   ::= { raisecomAlarmPortEntry 4 } 

				raisecomAlarmPortEvList OBJECT-TYPE
		               SYNTAX 	   PortAlarmEventList 
                       MAX-ACCESS  read-only
                       STATUS      current    
                       DESCRIPTION  
                       		"The current alarm information on port."
        		  	   ::= { raisecomAlarmPortEntry 5 } 

        	--raisecomAlarmHist  Information
        	raisecomAlarmHistory    OBJECT IDENTIFIER ::= { raisecomAlarm 7 }
        		  	   
        	raisecomAlarmHistTable OBJECT-TYPE
					SYNTAX		SEQUENCE OF	RaisecomAlarmHistEntry
					MAX-ACCESS	not-accessible
					STATUS		current
					DESCRIPTION
						 "A table of history alarm information.."
					::=	{  raisecomAlarmHistory 1 } 
				
				raisecomAlarmHistEntry  OBJECT-TYPE
						SYNTAX		RaisecomAlarmHistEntry
						MAX-ACCESS	not-accessible
						STATUS		current
						DESCRIPTION
						   	"Table entry for history alarm information."
						INDEX {	raisecomAlarmHistIndex }
						::=	{ raisecomAlarmHistTable 1 } 	  
						            
			    RaisecomAlarmHistEntry ::= SEQUENCE {
			        raisecomAlarmHistIndex         	INTEGER,
			        raisecomAlarmHistStatus     	INTEGER,
			        raisecomAlarmHistSource      	INTEGER,
			        raisecomAlarmHistDescr      	OCTET STRING,
			        raisecomAlarmHistTimestamp    	INTEGER,
			        raisecomAlarmHistType           INTEGER
				    }
				
			    raisecomAlarmHistIndex OBJECT-TYPE
						SYNTAX		INTEGER
						MAX-ACCESS	not-accessible
						STATUS		current
						DESCRIPTION
							"This object index of alarm history entry."
						::=	{ raisecomAlarmHistEntry 1 }
				
				raisecomAlarmHistStatus OBJECT-TYPE
		               SYNTAX INTEGER { 
 	                               high-volt-cleared(1),
 	                               low-volt-cleared(2),
 	                               high-temperature-cleared(3),  
 	                               low-temperature-cleared(4)
		                           }  
                       MAX-ACCESS  read-only
                       STATUS      current    
                       DESCRIPTION  
                       		"The status of alarm informationasserted:alarm has generated,
                       		 cleared:alarm is cleared, clearall:all of alarm is cleared."
        		  	   ::= { raisecomAlarmHistEntry 2 } 

        		raisecomAlarmHistSource   OBJECT-TYPE
		               SYNTAX INTEGER 
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The source of alarm informationswitch or port."
        		  	   ::= { raisecomAlarmHistEntry 3 } 

			    raisecomAlarmHistDescr OBJECT-TYPE
	  				SYNTAX OCTET STRING (SIZE (0..64))
					ACCESS read-only
					STATUS current
					DESCRIPTION
						"The description of alarm information."
					    ::= { raisecomAlarmHistEntry 4 }
        		  	   
        		raisecomAlarmHistTimestamp   OBJECT-TYPE
		               SYNTAX INTEGER 
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The timestamp of alarm information."
        		  	   ::= { raisecomAlarmHistEntry 5 } 

				raisecomAlarmHistType OBJECT-TYPE
		               SYNTAX INTEGER { 
		                           dev-power-down(0),
		                           power-abnormal(1),
		                           high-temperature(2),
		                           low-temperature(3), 	
		                           high-volt(4),
		                           low-volt(5),
		                           link-down(6), 
		                           link-falut(7), 
		                           not-forward(8),
		                           power-normal(9),
		                           normal-high-temperature(10), 
		                           normal-high-volt(11),
		                           link-up(12),
		                           link-ok(13), 
		                           forward(14),
		                           all-alarm(15),
								   offline(16),
								   online(17),
								   power-on(18),
								   normal-low-temperature(19), 
		                           normal-low-volt(20)
		                           }  
                       MAX-ACCESS  read-only
                       STATUS      current    
                       DESCRIPTION  
                       		"The type of alarm information."
        		  	   ::= { raisecomAlarmHistEntry 6 } 

        	--Alarm Curent Information
        	raisecomAlarmCurrent    OBJECT IDENTIFIER ::= { raisecomAlarm 8 }
        		  	   
        	raisecomAlarmCurtTable OBJECT-TYPE
					SYNTAX		SEQUENCE OF	RaisecomAlarmCurtEntry
					MAX-ACCESS	not-accessible
					STATUS		current
					DESCRIPTION
						 "A table of current alarm information.."
					::=	{  raisecomAlarmCurrent 1 } 
				
				raisecomAlarmCurtEntry  OBJECT-TYPE
						SYNTAX		RaisecomAlarmCurtEntry
						MAX-ACCESS	not-accessible
						STATUS		current
						DESCRIPTION
						   	"Table entry for current alarm information."
						INDEX {	raisecomAlarmCurtIndex }
						::=	{ raisecomAlarmCurtTable 1 } 	  
						            
			    RaisecomAlarmCurtEntry ::= SEQUENCE {
			        raisecomAlarmCurtIndex         	INTEGER,
			        raisecomAlarmCurtSource      	INTEGER,
			        raisecomAlarmCurtDescr    		OCTET STRING,
			        raisecomAlarmCurtTimestamp    	INTEGER,
			        raisecomAlarmCurtType           INTEGER
				    }
				
			    raisecomAlarmCurtIndex OBJECT-TYPE
						SYNTAX		INTEGER
						MAX-ACCESS	not-accessible
						STATUS		current
						DESCRIPTION
							"This object index of alarm current entry."
						::=	{ raisecomAlarmCurtEntry 1 }
				
        		raisecomAlarmCurtSource   OBJECT-TYPE
		               SYNTAX INTEGER 
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The source of alarm informationswitch or port."
        		  	   ::= { raisecomAlarmCurtEntry 2 } 

			    raisecomAlarmCurtDescr OBJECT-TYPE
	  				SYNTAX OCTET STRING (SIZE (0..64))
					ACCESS read-only
					STATUS current
					DESCRIPTION
						"The description of alarm information."
					    ::= { raisecomAlarmCurtEntry 3 }
        		  	   
        		raisecomAlarmCurtTimestamp   OBJECT-TYPE
		               SYNTAX INTEGER 
                       MAX-ACCESS  read-only
                       STATUS      current
                       DESCRIPTION  
                       		"The timestamp of alarm information."
        		  	   ::= { raisecomAlarmCurtEntry 4 } 

				raisecomAlarmCurtType OBJECT-TYPE
		               SYNTAX INTEGER { 
		                           dev-power-down(0),
		                           power-abnormal(1),
		                           high-temperature(2),
		                           low-temperature(3),
		                           high-volt(4),
		                           low-volt(5),
		                           link-down(6),
		                           link-falut(7),
		                           not-forward(8)
		                           }  
                       MAX-ACCESS  read-only
                       STATUS      current    
                       DESCRIPTION  
                       		"The type of alarm information."
        		  	   ::= { raisecomAlarmCurtEntry 5 } 

END  