AC-PM-ATM-MIB DEFINITIONS ::= BEGIN


    IMPORTS
       

        OBJECT-TYPE, 
        MODULE-IDENTITY                             FROM SNMPv2-SMI
        enterprises                                 FROM SNMPv2-SMI;
	

	audioCodes       OBJECT IDENTIFIER ::= {enterprises 5003}
	acRegistrations  OBJECT IDENTIFIER ::= {audioCodes 7}
	acGeneric        OBJECT IDENTIFIER ::= {audioCodes 8}
	acProducts       OBJECT IDENTIFIER ::= {audioCodes 9}	
	acPerformance    OBJECT IDENTIFIER ::= {audioCodes 10}	

       
acPMAtm  MODULE-IDENTITY       
    LAST-UPDATED "200601261643Z"          --Thursday, January 26, 2006
    ORGANIZATION "AudioCodes Ltd"
    CONTACT-INFO
    "Postal: Support
			 AudioCodes LTD
             1 Hayarden Street
             Airport City 
			 Lod, ISRAEL 70151
     Tel:    972-3-9764000
     Fax:    972-3-9764040
     Email:  support@audiocodes.com
     Web:    www.audiocodes.com"		
		

    DESCRIPTION       
    "The AC-PM-ATM MIB offers performance monitoring
For the ATMrelated elements in Audiocodes' devices.
The Configuration sub-tree is for configuring the interval
Period length for the entire AC-PM-ATM MIB, and the 
different tables' thresholds.
The Data sub-tree presents the tables of monitored
elements.

Note  - for the entire MIB the value (-1) means the value
Asked for is either not supported or currently not relevant
(this is for when values asked for are for intervals not yet
recorded."

        REVISION     "201006041528Z"          --Tuesday, April 06, 2010 

        DESCRIPTION  "obsoleted acPMAtm"



    ::= {acPerformance 12}  








     acPMAtmConfiguration          OBJECT IDENTIFIER ::= {acPMAtm 1}


     acPMAtmConfigurationPeriodLength OBJECT-TYPE
       SYNTAX INTEGER (0..894780)
       MAX-ACCESS read-write
       STATUS obsolete
       DESCRIPTION
           "Length of monitoring intervals for entire MIB.Time is in minutes."
       ::= {acPMAtmConfiguration 1}



     acPMAtmConfigurationResetTotalCounters OBJECT-TYPE
       SYNTAX INTEGER {
                  resetCountersDone(1)
,
                  resetTotalCounters(2)

                  }
       MAX-ACCESS read-write
       STATUS obsolete
       DESCRIPTION
           "Total-Counters Reset.  To reset the total counters, set the
value of this object to resetTotalCounters(2)."
       ::= {acPMAtmConfiguration 2}



     acPMAtmCellAttributes         OBJECT IDENTIFIER ::= {acPMAtmConfiguration 31}


     acPMAtmCellAttributesTxHighThreshold OBJECT-TYPE
       SYNTAX INTEGER (100..3000)
       MAX-ACCESS read-write
       STATUS obsolete
       DESCRIPTION
           "High threshold."
       ::= {acPMAtmCellAttributes 1}



     acPMAtmCellAttributesTxLowThreshold OBJECT-TYPE
       SYNTAX INTEGER (100..3000)
       MAX-ACCESS read-write
       STATUS obsolete
       DESCRIPTION
           "Low threshold."
       ::= {acPMAtmCellAttributes 2}



     acPMAtmCellAttributesRxHighThreshold OBJECT-TYPE
       SYNTAX INTEGER (100..3000)
       MAX-ACCESS read-write
       STATUS obsolete
       DESCRIPTION
           "High threshold."
       ::= {acPMAtmCellAttributes 3}



     acPMAtmCellAttributesRxLowThreshold OBJECT-TYPE
       SYNTAX INTEGER (100..3000)
       MAX-ACCESS read-write
       STATUS obsolete
       DESCRIPTION
           "Low threshold."
       ::= {acPMAtmCellAttributes 4}



     acPMAtmData                   OBJECT IDENTIFIER ::= {acPMAtm 2}


     acPMAtmDataAcPMAtmTimeFromStartOfInterval OBJECT-TYPE
       SYNTAX INTEGER (0..2147483647)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "The time in seconds since the start of the current interval.
MIB specific."
       ::= {acPMAtmData 1}



     -- ****************************************
     -- acPMAtmCellTx table decleration
     -- ****************************************
     acPMAtmCellTxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMAtmCellTxEntry
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           "Atm interface transmit cells per second."
       ::= {acPMAtmData 21}



     -- ****************************************
     -- acPMAtmCellTx table entry
     -- ****************************************
     acPMAtmCellTxEntry OBJECT-TYPE
       SYNTAX AcPMAtmCellTxEntry
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           ""
       INDEX {acPMAtmCellTxInterface,acPMAtmCellTxInterval}
       ::= {acPMAtmCellTxTable 1}



     -- ****************************************
     -- acPMAtmCellTx TABLE
     -- ****************************************
     AcPMAtmCellTxEntry ::= SEQUENCE {
       acPMAtmCellTxInterface                                      INTEGER,
       acPMAtmCellTxInterval                                       INTEGER,
       acPMAtmCellTxAverage                                        INTEGER,
       acPMAtmCellTxMax                                            INTEGER,
       acPMAtmCellTxMin                                            INTEGER,
       acPMAtmCellTxVolume                                         Counter32,
       acPMAtmCellTxTimeBelowLowThreshold                          INTEGER,
       acPMAtmCellTxTimeBetweenThresholds                          INTEGER,
       acPMAtmCellTxTimeAboveHighThreshold                         INTEGER,
       acPMAtmCellTxFullDayAverage                                 INTEGER
     }



     acPMAtmCellTxInterface OBJECT-TYPE
       SYNTAX INTEGER (0..2)
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           "Atm interface 0,1 and 2."
       ::= {acPMAtmCellTxEntry 1}



     acPMAtmCellTxInterval OBJECT-TYPE
       SYNTAX INTEGER (0..2)
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMAtmCellTxEntry 2}



     acPMAtmCellTxAverage OBJECT-TYPE
       SYNTAX INTEGER (-1..2147483647)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMAtmCellTxEntry 3}



     acPMAtmCellTxMax OBJECT-TYPE
       SYNTAX INTEGER (-1..2147483647)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMAtmCellTxEntry 4}



     acPMAtmCellTxMin OBJECT-TYPE
       SYNTAX INTEGER (-1..2147483647)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMAtmCellTxEntry 5}



     acPMAtmCellTxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Activity volume."
       ::= {acPMAtmCellTxEntry 6}



     acPMAtmCellTxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX INTEGER (-1..100)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMAtmCellTxEntry 7}



     acPMAtmCellTxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX INTEGER (-1..100)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMAtmCellTxEntry 8}



     acPMAtmCellTxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX INTEGER (-1..100)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMAtmCellTxEntry 9}



     acPMAtmCellTxFullDayAverage OBJECT-TYPE
       SYNTAX INTEGER (-1..2147483647)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMAtmCellTxEntry 10}



     -- ****************************************
     -- acPMAtmCellRx table decleration
     -- ****************************************
     acPMAtmCellRxTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMAtmCellRxEntry
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           "Atm interface recieve cells per second."
       ::= {acPMAtmData 22}



     -- ****************************************
     -- acPMAtmCellRx table entry
     -- ****************************************
     acPMAtmCellRxEntry OBJECT-TYPE
       SYNTAX AcPMAtmCellRxEntry
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           ""
       INDEX {acPMAtmCellRxInterface,acPMAtmCellRxInterval}
       ::= {acPMAtmCellRxTable 1}



     -- ****************************************
     -- acPMAtmCellRx TABLE
     -- ****************************************
     AcPMAtmCellRxEntry ::= SEQUENCE {
       acPMAtmCellRxInterface                                      INTEGER,
       acPMAtmCellRxInterval                                       INTEGER,
       acPMAtmCellRxAverage                                        INTEGER,
       acPMAtmCellRxMax                                            INTEGER,
       acPMAtmCellRxMin                                            INTEGER,
       acPMAtmCellRxVolume                                         Counter32,
       acPMAtmCellRxTimeBelowLowThreshold                          INTEGER,
       acPMAtmCellRxTimeBetweenThresholds                          INTEGER,
       acPMAtmCellRxTimeAboveHighThreshold                         INTEGER,
       acPMAtmCellRxFullDayAverage                                 INTEGER
     }



     acPMAtmCellRxInterface OBJECT-TYPE
       SYNTAX INTEGER (0..2)
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           "Atm interface 0,1 and 2."
       ::= {acPMAtmCellRxEntry 1}



     acPMAtmCellRxInterval OBJECT-TYPE
       SYNTAX INTEGER (0..2)
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMAtmCellRxEntry 2}



     acPMAtmCellRxAverage OBJECT-TYPE
       SYNTAX INTEGER (-1..2147483647)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Average value within the period time."
       ::= {acPMAtmCellRxEntry 3}



     acPMAtmCellRxMax OBJECT-TYPE
       SYNTAX INTEGER (-1..2147483647)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Maximum value within the period time."
       ::= {acPMAtmCellRxEntry 4}



     acPMAtmCellRxMin OBJECT-TYPE
       SYNTAX INTEGER (-1..2147483647)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Minimum value within the period time."
       ::= {acPMAtmCellRxEntry 5}



     acPMAtmCellRxVolume OBJECT-TYPE
       SYNTAX Counter32
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Activity volume."
       ::= {acPMAtmCellRxEntry 6}



     acPMAtmCellRxTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX INTEGER (-1..100)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMAtmCellRxEntry 7}



     acPMAtmCellRxTimeBetweenThresholds OBJECT-TYPE
       SYNTAX INTEGER (-1..100)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMAtmCellRxEntry 8}



     acPMAtmCellRxTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX INTEGER (-1..100)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMAtmCellRxEntry 9}



     acPMAtmCellRxFullDayAverage OBJECT-TYPE
       SYNTAX INTEGER (-1..2147483647)
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMAtmCellRxEntry 10}



     -- ****************************************
     -- acPMAtmCellDiscarded table decleration
     -- ****************************************
     acPMAtmCellDiscardedTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMAtmCellDiscardedEntry
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           "Counts the number of cells discarded in the reporting interval."
       ::= {acPMAtmData 23}



     -- ****************************************
     -- acPMAtmCellDiscarded table entry
     -- ****************************************
     acPMAtmCellDiscardedEntry OBJECT-TYPE
       SYNTAX AcPMAtmCellDiscardedEntry
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           ""
       INDEX {acPMAtmCellDiscardedInterface,acPMAtmCellDiscardedInterval}
       ::= {acPMAtmCellDiscardedTable 1}



     -- ****************************************
     -- acPMAtmCellDiscarded TABLE
     -- ****************************************
     AcPMAtmCellDiscardedEntry ::= SEQUENCE {
       acPMAtmCellDiscardedInterface                               INTEGER,
       acPMAtmCellDiscardedInterval                                INTEGER,
       acPMAtmCellDiscardedVal                                     Gauge32
     }



     acPMAtmCellDiscardedInterface OBJECT-TYPE
       SYNTAX INTEGER (0..2)
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           "Atm interface 0,1 and 2."
       ::= {acPMAtmCellDiscardedEntry 1}



     acPMAtmCellDiscardedInterval OBJECT-TYPE
       SYNTAX INTEGER (0..2)
       MAX-ACCESS not-accessible
       STATUS obsolete
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMAtmCellDiscardedEntry 2}



     acPMAtmCellDiscardedVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS obsolete
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMAtmCellDiscardedEntry 3}





END