ARRIS-C3-MAC-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, TimeInterval, RowStatus, TruthValue, DisplayString
        FROM SNMPv2-TC
    ifIndex
        FROM IF-MIB      -- RFC2233
    TenthdBmV
        FROM DOCS-IF-MIB  -- RFC2670
    TenthdB
        FROM DOCS-IF-MIB  -- RFC2670
    cmtsC3
        FROM ARRIS-MIB;

    cmtsC3MACMIB  MODULE-IDENTITY
        LAST-UPDATED "200412030000Z" -- 3nd Dec 2004
        ORGANIZATION "Arris International"
        CONTACT-INFO
            "   Network Management
                Postal: Arris International.
                        4400 Cork Airport Business Park
                        Cork Airport, Kinsale Road
                        Cork, Ireland.
                Tel:    +353 21 7305 800
                Fax:    +353 21 4321 972"

        DESCRIPTION
            "This MIB manages the MAC software on the Cadant C3 CMTS."
        REVISION "200411210000Z"
        DESCRIPTION
            "Changes to support fully programmable IF frequency.
             Added support for downstream wireless mode.
             Updated some mib descriptions for clarity and typos.
             Added mixed mode to DocsisMacType definition which defines a
             docsis downstream and euro-docsis upstream configuration that is
             used by some customers in lieu of annex C mode which the CMTS does
             not support in hardware.
             Added support for downstream wireless mode."
        REVISION "200411260000Z"
        DESCRIPTION
            "Added dcxMACUpChannelinitialRangingDelay."
        REVISION "200412030000Z"
        DESCRIPTION
            "Added dcxMACUccMaxFailedAttempts."
        ::= { cmtsC3 6 }

    DocsisMacType ::= TEXTUAL-CONVENTION 
        STATUS			current 
        DESCRIPTION		"Indicates the DOCSIS Channel Type." 
        SYNTAX			INTEGER { 
                                docsis (1), 
                                euroDocsis (2), 
                                mixed (3), 
                                custom(4)
        }

    dcxMACObjects OBJECT IDENTIFIER ::= { cmtsC3MACMIB 1 }

    dcxMACCmtsMacTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF DcxMACCmtsMacEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Additional columns for docsIfCmtsMacTable.
                An entry in this table exists for each ifEntry with an 
                ifType of docsCableMaclayer(127)."
        ::= { dcxMACObjects 1 }

    dcxMACCmtsMacEntry OBJECT-TYPE
        SYNTAX DcxMACCmtsMacEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION 
            "dcxMACCmtsMacEntry"
        INDEX {ifIndex}
        ::= { dcxMACCmtsMacTable 1 }

    DcxMACCmtsMacEntry ::= SEQUENCE {
        dcxMACCmtsMacMode DocsisMacType,
        dcxMACCableAdvanceType INTEGER,
        dcxMACPlantLength Unsigned32,
        dcxMACFlapAgingTime Unsigned32,
        dcxMACFlapInsertTime Unsigned32,
        dcxMACFlapMissThresh Unsigned32,
        dcxMACFlapListSize Unsigned32,
        dcxMACCmOfflineAgingTime Unsigned32,
        dcxMACUccMaxFailedAttempts Unsigned32
        }

    dcxMACCmtsMacMode OBJECT-TYPE
        SYNTAX      DocsisMacType
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Indicates the mode in which the MAC is operating. A read to this
            value may return any of the modes defined by DocsisMacType. Only
            the modes docsis, euroDocsis and mixed may be written.
            When set to docsis or euroDocsis, all downstream and upstream
            channels in this MAC domain will be configured in DOCSIS or
            EuroDOCSIS mode respectively. When set to mixed, the downstream
            channels will be configured in DOCSIS and the upstream channels
            will be running in EuroDOCSIS mode.
            The value custom will be returned in a read operation if any of
            the underlying channels has been reconfigured in such a way that
            the MAC can not be described a docsis, euroDocsis or mixed."
        ::= { dcxMACCmtsMacEntry 1 }
        

    dcxMACCableAdvanceType OBJECT-TYPE
        SYNTAX      INTEGER { static(0), dynamic(1) }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Cable Map Advance Type - 0 for Static, 1 for Dynamic."
        ::= { dcxMACCmtsMacEntry 2 }
        
        
    dcxMACPlantLength OBJECT-TYPE
        SYNTAX      Unsigned32 (0..161)
        UNITS       "kilometers"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Cable Plant Length (1-way) in kilometers."
        ::= { dcxMACCmtsMacEntry 3 }
        
        
    dcxMACFlapAgingTime OBJECT-TYPE
        SYNTAX      Unsigned32 (0..864000)
        UNITS       "seconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Cable Flap List Aging Time in seconds."
        ::= { dcxMACCmtsMacEntry 4 }
        
        
    dcxMACFlapInsertTime OBJECT-TYPE
        SYNTAX      Unsigned32 ( 0..86400 )
        UNITS       "seconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Cable Flap List Insertion Time threshold in seconds."
        ::= { dcxMACCmtsMacEntry 5 }
        
        
    dcxMACFlapMissThresh OBJECT-TYPE
        SYNTAX      Unsigned32 (0..12)
        UNITS       "misses"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Cable Flap List Miss Threshold in misses."
        ::= { dcxMACCmtsMacEntry 6 }
        
        
    dcxMACFlapListSize OBJECT-TYPE
        SYNTAX      Unsigned32 (0..6000)
        UNITS       "entries"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Cable Flap List Maximum Number of Entries."
        ::= { dcxMACCmtsMacEntry 8 }

        
    dcxMACCmOfflineAgingTime OBJECT-TYPE
        SYNTAX      Unsigned32 (3600..864000)
        UNITS       "seconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Cable modem offline aging time in seconds. Minimum value
            is 1 hour. Maximum time before aging a modem is 10 days.
            Default value is 24 hours."
        DEFVAL { 86400 }
        ::= { dcxMACCmtsMacEntry 9 }

        
    dcxMACUccMaxFailedAttempts OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Maximum number of consecutive failed channel change attempts that
            a modem is allowed before the CMTS decides to no longer use the
            modem for load balancing purposes.
            If a modem successfully completes a channel change before the
            maximum number of attempts is reached, the number of consecutive
            failed attempts for the modem is reset.
            A value of 0 indicates no limit."
        DEFVAL { 2 }
        ::= { dcxMACCmtsMacEntry 10 }


    dcxMACDownstreamChannelTable    OBJECT-TYPE
        SYNTAX  SEQUENCE OF DcxMACDownstreamChannelEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Additional columns for docsIfDownstreamChannelTable.
                An entry in this table exists for each ifEntry with an 
                ifType of docsCableDownstream(128)."
        ::= { dcxMACObjects 2 }

    dcxMACDownstreamChannelEntry OBJECT-TYPE
        SYNTAX DcxMACDownstreamChannelEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION 
            "dcxMACDownstreamChannelEntry"
        INDEX {ifIndex}
        ::= { dcxMACDownstreamChannelTable 1 }

    DcxMACDownstreamChannelEntry ::= SEQUENCE {
        dcxMACDownChannelMacMode DocsisMacType,
        dcxMACDownChannelUpconverter INTEGER,
        dcxMACDownChannelIfFrequency Integer32,
        dcxMACDownChannelWirelessMode INTEGER,
        dcxMACDownChannelSymbolRate Integer32,
        dcxMACDownChannelAlpha Integer32
        }

    dcxMACDownChannelMacMode OBJECT-TYPE
        SYNTAX      DocsisMacType
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Configures the downstream to DOCSIS or EuroDOCSIS.
            When dcxMACDownChannelWirelessMode is disabled, changes to this
            will impact the downstream annex type, modulation, symbol rate
            and interleaver. When wireless mode is enabled, only the annex
            type and interleaver will be changed."
        ::= { dcxMACDownstreamChannelEntry 1 }

    dcxMACDownChannelUpconverter OBJECT-TYPE
        SYNTAX      INTEGER { internal(1), external(2) }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Controls whether or not the internal upconverter is used.
             If set to internal, the downstream IF frequency will operate
             in read-only mode and will be configured internally by the
             CMTS based on the downstream channel configuration.
             If set to external, the IF frequency may be programmed to set the
             frequency supplied to an external upconverter via the IF output.
             In this mode, the downstream RF frequency and power will both
             return 0 when read."
        ::= { dcxMACDownstreamChannelEntry 2 }

    dcxMACDownChannelIfFrequency OBJECT-TYPE
        SYNTAX      Integer32 (10000000..60000000)
        UNITS       "hertz"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The IF frequency output by the modulator for this channel."
        ::= { dcxMACDownstreamChannelEntry 3 }
        
    dcxMACDownChannelWirelessMode OBJECT-TYPE
        SYNTAX      INTEGER { active(1), inactive(2) }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Enabling this mode allows non-standard downstream modulations and
            symbol rates to be configured which are suitable when using the
            CMTS in a wireless application. Changes to dcxMACDownChannelMacMode
            when wireless mode is active will only impact the downstream annex
            type and interleaver settings. Modulation and symbol rates will
            only be affected when wireless mode is disabled.
            Disabling wireless mode will reset any non-standard modulation and
            symbol rates settings in order to restore a standard DOCSIS or
            EuroDOCSIS downstream.
            If a set to active fails, a license may be required to activate the
            feature."
        ::= { dcxMACDownstreamChannelEntry 4 }

    dcxMACDownChannelSymbolRate OBJECT-TYPE
        SYNTAX      Integer32 (1250000..6952000)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Sets the downstream symbol rate."
        ::= { dcxMACDownstreamChannelEntry 5 }
        
    dcxMACDownChannelAlpha OBJECT-TYPE
        SYNTAX      Integer32
        UNITS        "percent"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The percentage of excess bandwidth for the channel."
        ::= { dcxMACDownstreamChannelEntry 6 }

    dcxMACUpstreamChannelTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF DcxMACUpstreamChannelEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Additional columns for docsIfUpstreamChannelTable.
                An entry in this table exists for each ifEntry with an 
                ifType of docsCableUpstream(129)."
        ::= { dcxMACObjects 3 }

    dcxMACUpstreamChannelEntry OBJECT-TYPE
        SYNTAX DcxMACUpstreamChannelEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION 
            "dcxMACUpstreamChannelEntry"
        INDEX {ifIndex}
        ::= { dcxMACUpstreamChannelTable 1 }

    DcxMACUpstreamChannelEntry ::= SEQUENCE {
        dcxMACUpChannelMacMode DocsisMacType,
        dcxMACUpChannelAmpAttenuation TenthdBmV,
        dcxMACUpChannelIngressCancellation INTEGER,
        dcxMACUpChannelGroupId Unsigned32,
        dcxMACUpChannelShortPollInterval TimeInterval,
        dcxMACUpChannelPeriodicPollInterval TimeInterval,
        dcxMACUpChannelInputPowerMode INTEGER,
        dcxMACUpChannelPower TenthdBmV,
        dcxMACUpChannelPlantLength Unsigned32,
        dcxMACUpChannelMaxCmMapProcTime Unsigned32,
        dcxMACUpChannelConcatenation TruthValue,
        dcxMACUpChannelSpMgtTriggerIndex Unsigned32,
        dcxMACUpChannelLowPowerOffset TenthdBmV,
        dcxMACUpChannelHighPowerOffset TenthdBmV,
        dcxMACUpChannelLogSnrAveTimeconstant Unsigned32,
        dcxMACUpChannelImpulseMitigation INTEGER,
        dcxMACUpChannelRngPreambleGuardSymbols Unsigned32,
        dcxMACUpChannelNrngPreambleGuardSymbols Unsigned32,
        dcxMACUpChannelExtendedFrequencyErrorDetect INTEGER,
        dcxMACUpChannelLogC3SnrTimeconstant Unsigned32,
        dcxMACUpChannelSignalNoise TenthdB,
        dcxMACUpChannelSafeConfig TruthValue,
        dcxMACUpChannelInitialRangingDelay Unsigned32
        }

    dcxMACUpChannelMacMode OBJECT-TYPE
        SYNTAX      DocsisMacType
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Indicates the mode in which this upstream is operating. A read or
            write to this may consist only of the values docsis or euroDocsis."
        ::= { dcxMACUpstreamChannelEntry 1 }
    
    dcxMACUpChannelAmpAttenuation OBJECT-TYPE
        SYNTAX      TenthdBmV
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The amplifier attenuation level for this logical 
            channel."
        ::= { dcxMACUpstreamChannelEntry 2 }
    
    dcxMACUpChannelIngressCancellation OBJECT-TYPE
        SYNTAX      INTEGER { disabled(1), tdmaOnly(2), scdmaSec(3), scdmaInc1(4), scdmaInc2(5) }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Sets the ingress noise cancellation mode for this
            logical channel. Not all modes may be valid for a
            given logical channel configuration or hardware."
        ::= { dcxMACUpstreamChannelEntry 3 }

    dcxMACUpChannelGroupId OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The group ID for this logical channel used to associate it 
            with other upsteams on the same physical network. The group ID 
            is an index into the dcxMACUpstreamGroupTable which defines common 
            parameters for grouped upsteams. Upstreams do not have to be 
            grouped and there may be more than one group on the same physical 
            network. Spatially diverse upstreams should not have the same group ID."
        ::= { dcxMACUpstreamChannelEntry 4 }

    dcxMACUpChannelShortPollInterval OBJECT-TYPE
        SYNTAX      TimeInterval (1..100)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The short interval for initial unicast maintanance on this logical 
            channel."
        ::= { dcxMACUpstreamChannelEntry 5 }

    dcxMACUpChannelPeriodicPollInterval OBJECT-TYPE
        SYNTAX      TimeInterval (100..10000)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The periodic station maintanance interval on this logical channel."
        ::= { dcxMACUpstreamChannelEntry 6 }
    
    dcxMACUpChannelInputPowerMode OBJECT-TYPE
        SYNTAX      INTEGER { fixed(1), automatic(2) }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The receiver input power mode for this logical channel. In fixed
            mode the input power to the demodulator will remain fixed across 
            symbol rate changes. In automatic mode the demodulator may vary the 
            input power for optimal performance."
        ::= { dcxMACUpstreamChannelEntry 7 }
        
    dcxMACUpChannelPower OBJECT-TYPE
        SYNTAX      TenthdBmV
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The nominal receiver input  power for this logical channel."
        ::= { dcxMACUpstreamChannelEntry 8 }
    
    dcxMACUpChannelPlantLength OBJECT-TYPE
        SYNTAX      Unsigned32 (1..320)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
                "The cable length in km to the most distant CM on this logical 
                upstream."
            ::= { dcxMACUpstreamChannelEntry 9 }
            
    dcxMACUpChannelMaxCmMapProcTime OBJECT-TYPE
        SYNTAX      Unsigned32 (0..1000000)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The maximum time in microseconds allowed for modems on this logical 
            channel to process the Upstream Bandwidth Allocation MAP."
        ::= { dcxMACUpstreamChannelEntry 10 }

    dcxMACUpChannelConcatenation OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Enables or disables the use of packet concatenation by Cable Modems on 
            this logical channel."
        ::= { dcxMACUpstreamChannelEntry 11 }
    
    dcxMACUpChannelSpMgtTriggerIndex OBJECT-TYPE
        SYNTAX      Unsigned32 (0..255)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "An index into spectral management trigger table, identical 
            to dcxMACSpMgtTriggerIndex in that table. All entries with 
            the same value of dcxMACSpMgtTriggerIndex form a trigger group 
            all assigned to the same logical upstream channel or group. 
            Returns 0 if there are no triggers assigned to this logical 
            channel."
        ::= { dcxMACUpstreamChannelEntry 12 }
        

    dcxMACUpChannelLowPowerOffset OBJECT-TYPE
        SYNTAX      TenthdBmV  (-100..-10)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The maximum power offset of a burst below the nominal
            input power to the CMTS that will not cause a RNG-RSP
            with status continue. Valid range is from -10 dBmV to
            -1 dBmV in 1 dB increments."
        DEFVAL { -60 }
        ::= { dcxMACUpstreamChannelEntry 13 }


    dcxMACUpChannelHighPowerOffset OBJECT-TYPE
        SYNTAX      TenthdBmV  (10..100)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The maximum power offset of a burst above the nominal
            input power to the CMTS that will not cause a RNG-RSP
            with status continue. Valid range is from +1 dBmV to
            +10 dBmV in 1 dB increments."
        DEFVAL { 60 }
        ::= { dcxMACUpstreamChannelEntry 14 }
    
    dcxMACUpChannelLogSnrAveTimeconstant OBJECT-TYPE
        SYNTAX      Unsigned32 (0..10)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The averaging timeconstant used to calculate the per-logical channel 
            MIB variable docsIfSigQSignalNoise. The averaging uses a logarithmic
            scale, so that the actual timeconstant used is 2^X, where X is the
            value configured for this object. Increasing the value of X increases
            the degree to which the SNR results are averaged over time, and reduces
            the sensitivity of the reported channel SNR to local oscillations in
            signal quality. Averaging can effectively be disabled by setting this
            object to 0"
        DEFVAL { 2 }
        ::= { dcxMACUpstreamChannelEntry 15 }
    
    dcxMACUpChannelImpulseMitigation OBJECT-TYPE
        SYNTAX      INTEGER { enabled(1), disabled(2) }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Enables or disables impulse noise mitigation for this 
            logical channel."
        ::= { dcxMACUpstreamChannelEntry 16 }
    
    dcxMACUpChannelRngPreambleGuardSymbols OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Number of guard symbols before the preamble pilot pattern for 
            ranging bursts. Guard symbols may help the receiver to mitigate 
            the effects of ISI and\or help with the detection of bursts with 
            an early arrival time"
        ::= { dcxMACUpstreamChannelEntry 17 }
    
    dcxMACUpChannelNrngPreambleGuardSymbols OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Number of guard symbols before the preamble pilot pattern for 
            non-ranging bursts. Guard symbols may help the receiver to mitigate 
            the effects of ISI and\or help with the detection of bursts with 
            an early arrival time"
        ::= { dcxMACUpstreamChannelEntry 18 }


    dcxMACUpChannelExtendedFrequencyErrorDetect OBJECT-TYPE
        SYNTAX      INTEGER { none(0),
                              initialRanging(1),
                              periodicRanging(2),
                              allRanging(3) }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Offsets in carrier frequency in the modem are corrected by the CMTS
            during ranging. Typically most if not all off the frequency error is
            removed in the initial ranging response with incremental changes removed
            during periodic ranging. If large frequency offsets are expected during
            initial or periodic ranging, this value may be configured to provide
            extended frequency offset detection and correction."
        DEFVAL { none }
        ::= { dcxMACUpstreamChannelEntry 19 }


    dcxMACUpChannelLogC3SnrTimeconstant OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The averaging timeconstant used to calculate the per-logical channel 
            MIB variable dcxMACUpChannelSignalNoise. The averaging uses a logarithmic
            scale, so that the actual timeconstant used is 2^X, where X is the
            value configured for this object. Increasing the value of X increases
            the degree to which the SNR results are averaged over time, and reduces
            the sensitivity of the reported channel SNR to local oscillations in
            signal quality. Averaging can effectively be disabled by setting this
            object to 0"
        ::= { dcxMACUpstreamChannelEntry 20 }
    
    
    dcxMACUpChannelSignalNoise OBJECT-TYPE
        SYNTAX      TenthdB
        UNITS       "dB" 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "A measurement of the average signal/noise ratio for the logical upstream.
            The averaging may be controlled using the dcxMACUpChannelLogC3SnrTimeconstant
            variable"
        ::= { dcxMACUpstreamChannelEntry 21 }
    
    
    dcxMACUpChannelSafeConfig OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "If true, MIB SETs which would cause this logical channel to go offline will return
            a failure"
        ::= { dcxMACUpstreamChannelEntry 22 }    

         
    dcxMACUpChannelInitialRangingDelay OBJECT-TYPE
        SYNTAX      Unsigned32 (300..3000)
        UNITS       "microseconds"
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "The number of extra microseconds to allow in a broadcast IUC3
             grant to compensate for modems that perform initial ranging later
             than expected."
        ::= { dcxMACUpstreamChannelEntry 23 }
    
    dcxMACUpstreamGroupTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF DcxMACUpstreamGroupEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Entries containing definitions for group IDs
                that can be associated with an upstream channel."
        ::= { dcxMACObjects 4 }

    dcxMACUpstreamGroupEntry OBJECT-TYPE
        SYNTAX DcxMACUpstreamGroupEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION 
            "dcxMACUpstreamGroupEntry"
        INDEX {
                dcxMACUpstreamGroupId
              }
        ::= { dcxMACUpstreamGroupTable 1 }

    DcxMACUpstreamGroupEntry ::= SEQUENCE {
        dcxMACUpstreamGroupId Unsigned32,
        dcxMACUpstreamGroupName OCTET STRING,
        dcxMACUpstreamGroupLoadBalancing INTEGER,
        dcxMACUpstreamGroupFrequencyIndex Unsigned32,
        dcxMACUpstreamGroupSpMgtTriggerIndex Unsigned32,
        dcxMACUpstreamGroupStatus RowStatus
        }

    dcxMACUpstreamGroupId OBJECT-TYPE
        SYNTAX      Unsigned32 (1..255)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "The ID for this group."
        ::= { dcxMACUpstreamGroupEntry 1 }
    
    dcxMACUpstreamGroupName OBJECT-TYPE
        SYNTAX      OCTET STRING (SIZE(1..63))
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The name associated with this group"
        ::= { dcxMACUpstreamGroupEntry 2 }
    
    dcxMACUpstreamGroupLoadBalancing OBJECT-TYPE
        SYNTAX      INTEGER { none(1), initialNumeric(2), periodic(3) }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Configures upstream load balancing for the group.
            Options are: none, initialNumeric, periodic.
            If set to none, no load balancing will be performed.
            If set to initialNumeric, the CMTS may redirect modems to other active upstream
            channels in the same group by setting the upstream channel ID override in the
            RNG-RSP at any time up to the point where the modem successfully completes
            periodic ranging. Once a modem has completed ranging it must be reset before it
            may be moved to another upstream. The modems in a group will be distributed
            evenly and numerically across the active channels in the group. When a modems
            performs initial ranging, it will be sent to the upsteam with the least number
            of active modems if the number of active modems on the current upsteam is greater
            than the average number of modems per upsteam in the group. All channels are
            treated equally when calculating loads.
            If a modem fails to range on the desired channel following a ranging overide,
            it will be allowed to remain on the channel on which it next performs initial
            ranging.
            If set to periodic, modems will be numerically distributed during initial ranging
            and then selectively moved after registration using UCC. Periodic load balancing
            will attempt to distribute the modems to maintain even bandwidth utilization across
            the channels in a group."
        DEFVAL { none }
        ::= { dcxMACUpstreamGroupEntry 3 }

    dcxMACUpstreamGroupFrequencyIndex OBJECT-TYPE
        SYNTAX      Unsigned32 (0..255)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "An index into upstream frequency table, identical to 
            dcxMACUpstreamFrequencyIndex in that table. All entries 
            with the same value of dcxMACUpstreamFrequencyIndex form 
            a spectral frequency group all assigned to the same 
            upstream group. Returns 0 if there are no triggers assigned 
            to this group."
        ::= { dcxMACUpstreamGroupEntry 4 }
    
    dcxMACUpstreamGroupSpMgtTriggerIndex OBJECT-TYPE
        SYNTAX      Unsigned32 (0..255)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "An index into spectral management trigger table, identical 
            to dcxMACSpMgtTriggerIndex in that table. All entries with 
            the same value of dcxMACSpMgtTriggerIndex form a trigger group 
            all assigned to the same upstream group or channel. Returns 0 if 
            there are no triggers assigned to this group."
        ::= { dcxMACUpstreamGroupEntry 5 }
        
    dcxMACUpstreamGroupStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Used to create rows in this table"
        ::= { dcxMACUpstreamGroupEntry 6 }
    


    dcxMACUpstreamFrequencyTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF DcxMACUpstreamFrequencyEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Describes the upstream spectrum available for use by one or more
                upstream groups. Entries are grouped by dcxMACUpstreamFrequencyIndex,
                with each group assigned to one or more upstream groups."
        ::= { dcxMACObjects 5 }

    dcxMACUpstreamFrequencyEntry OBJECT-TYPE
        SYNTAX DcxMACUpstreamFrequencyEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION 
            "Describes a single contiguous region of upstream spectrum, available for
            use by one or more upstream spectral groups."
        INDEX { dcxMACUpstreamFrequencyIndex, dcxMACUpstreamFrequencyRegion }
        ::= { dcxMACUpstreamFrequencyTable 1 }

    DcxMACUpstreamFrequencyEntry ::= SEQUENCE {
        dcxMACUpstreamFrequencyIndex Unsigned32,
        dcxMACUpstreamFrequencyRegion Unsigned32,
        dcxMACUpstreamFrequencyStart Integer32,
        dcxMACUpstreamFrequencyStop Integer32,
        dcxMACUpstreamFrequencyStatus RowStatus
        }

    dcxMACUpstreamFrequencyIndex OBJECT-TYPE
        SYNTAX      Unsigned32 (1..255)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An index into the upstream frequency table representing 
             a group of spectral regions, all associated with the 
             same upstream spectral group." 
        ::= { dcxMACUpstreamFrequencyEntry 1 }
    
    dcxMACUpstreamFrequencyRegion OBJECT-TYPE
        SYNTAX      Unsigned32 (1..255)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An index into the upstream frequency table which, when 
             grouped with other frequency regions with the same frequency
             index fully describe the upstream frequency spectrum available
             for use by a given spectral group." 
        ::= { dcxMACUpstreamFrequencyEntry 2 }
     
    dcxMACUpstreamFrequencyStart OBJECT-TYPE
        SYNTAX      Integer32
        UNITS       "hertz" 
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The start frequency for this upstream spectral region." 
        ::= { dcxMACUpstreamFrequencyEntry 3 }
    
    dcxMACUpstreamFrequencyStop OBJECT-TYPE
        SYNTAX      Integer32
        UNITS       "hertz" 
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "The stop frequency for this upstream spectral region." 
        ::= { dcxMACUpstreamFrequencyEntry 4 }
    
    dcxMACUpstreamFrequencyStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Used to create entries in this table." 
        ::= { dcxMACUpstreamFrequencyEntry 5 }
    
    
    dcxMACSpectralMgtObjects OBJECT IDENTIFIER ::= { dcxMACObjects 6 } 
    
    dcxMACSpectralMgtTriggerTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF DcxMACSpectralMgtTriggerEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Describes the spectral management triggers assigned to one 
                or more upstream groups or channels. Entries are grouped by 
                dcxMACSpMgtTriggerIndex, with each group assigned to one or more 
                upstream channels or groups."
        ::= { dcxMACSpectralMgtObjects 1 }

    dcxMACSpectralMgtTriggerEntry OBJECT-TYPE
        SYNTAX DcxMACSpectralMgtTriggerEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION 
            "Describes a single spectral management trigger, available for
            use by one or more upstream channels or spectral groups."
        INDEX { dcxMACSpMgtTriggerIndex, dcxMACSpMgtTriggerNumber }
        ::= { dcxMACSpectralMgtTriggerTable 1 }

    DcxMACSpectralMgtTriggerEntry::= SEQUENCE {
        dcxMACSpMgtTriggerIndex Unsigned32,
        dcxMACSpMgtTriggerNumber Unsigned32,
        dcxMACSpMgtTriggerType Integer32,
        dcxMACSpMgtTriggerAction Unsigned32,
        dcxMACSpMgtTriggerParam1 Integer32,
        dcxMACSpMgtTriggerParam2 Integer32,
        dcxMACSpMgtTriggerParam3 Integer32,
        dcxMACSpMgtTriggerParam4 Integer32,
        dcxMACSpMgtTriggerParam5 Integer32,
        dcxMACSpMgtTriggerParam6 Integer32,
        dcxMACSpMgtTriggerParam7 Integer32,
        dcxMACSpMgtTriggerParam8 Integer32,
        dcxMACSpMgtTriggerStatus RowStatus
        }

    dcxMACSpMgtTriggerIndex OBJECT-TYPE
        SYNTAX      Unsigned32 (0..255)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An index into the spectral managment trigger table 
            representing a group of triggers, all assigned to
             the same upstream channel or spectral group." 
        ::= { dcxMACSpectralMgtTriggerEntry 1 }
    
    dcxMACSpMgtTriggerNumber OBJECT-TYPE
        SYNTAX      Unsigned32 (1..255)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An index into the spectral managment trigger table which, 
            when grouped with other triggers with the same trigger
            index fully describe the spectral mangement triggers
            assigned to the same upstream channel or spectral group." 
        ::= { dcxMACSpectralMgtTriggerEntry 2 }
    
    dcxMACSpMgtTriggerType OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Identifies the trigger type represented by this entry." 
        ::= { dcxMACSpectralMgtTriggerEntry 3 }
    
    dcxMACSpMgtTriggerAction OBJECT-TYPE
        SYNTAX      Unsigned32 (1..255)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "An index into the spectral management action table,
            identical to dcxMACSpMgtActionIndex in that table,
            identifying the action to take if this trigger is
            invoked. Returns 0 if there is no action associated
            with this trigger." 
        ::= { dcxMACSpectralMgtTriggerEntry 4 }
    
    dcxMACSpMgtTriggerParam1 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Parameter dependent on trigger type." 
        ::= { dcxMACSpectralMgtTriggerEntry 5 }
    
    dcxMACSpMgtTriggerParam2 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Parameter dependent on trigger type." 
        ::= { dcxMACSpectralMgtTriggerEntry 6 }
     
    dcxMACSpMgtTriggerParam3 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Parameter dependent on trigger type." 
        ::= { dcxMACSpectralMgtTriggerEntry 7 }
    
    dcxMACSpMgtTriggerParam4 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Parameter dependent on trigger type." 
        ::= { dcxMACSpectralMgtTriggerEntry 8 }
     
    dcxMACSpMgtTriggerParam5 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Parameter dependent on trigger type." 
        ::= { dcxMACSpectralMgtTriggerEntry 9 }
     
    dcxMACSpMgtTriggerParam6 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Parameter dependent on trigger type." 
        ::= { dcxMACSpectralMgtTriggerEntry 10 }
     
    dcxMACSpMgtTriggerParam7 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Parameter dependent on trigger type." 
        ::= { dcxMACSpectralMgtTriggerEntry 11 }
     
    dcxMACSpMgtTriggerParam8 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Parameter dependent on trigger type." 
        ::= { dcxMACSpectralMgtTriggerEntry 12 }
    
    dcxMACSpMgtTriggerStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Used to create and control the status of entries in this table." 
        ::= { dcxMACSpectralMgtTriggerEntry 13 }
         
   
   
   dcxMACSpectralMgtActionTable  OBJECT-TYPE
        SYNTAX  SEQUENCE OF DcxMACSpectralMgtActionEntry
        MAX-ACCESS not-accessible
        STATUS     current
        DESCRIPTION
                "Describes the spectral management actions assigned to one 
                or more spectral managment triggers."
        ::= { dcxMACSpectralMgtObjects 2 }

    dcxMACSpectralMgtActionEntry OBJECT-TYPE
        SYNTAX DcxMACSpectralMgtActionEntry
        MAX-ACCESS  not-accessible
        STATUS  current
        DESCRIPTION 
            "Describes a single spectral management action, assigned to
            one or more spectral management triggers."
        INDEX { dcxMACSpMgtActionIndex }
        ::= { dcxMACSpectralMgtActionTable 1 }

    DcxMACSpectralMgtActionEntry::= SEQUENCE {
        dcxMACSpMgtActionIndex Unsigned32,
        dcxMACSpMgtActionType Integer32,
        dcxMACSpMgtActionParam1 Integer32,
        dcxMACSpMgtActionParam2 Integer32,
        dcxMACSpMgtActionParam3 Integer32,
        dcxMACSpMgtActionParam4 Integer32,
        dcxMACSpMgtActionParam5 Integer32,
        dcxMACSpMgtActionParam6 Integer32,
        dcxMACSpMgtActionParam7 Integer32,
        dcxMACSpMgtActionParam8 Integer32,
        dcxMACSpMgtActionStatus RowStatus
        }

    dcxMACSpMgtActionIndex OBJECT-TYPE
        SYNTAX      Unsigned32 (1..255)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "An index into the spectral managment actions table 
            used to assign actions to spectral management triggers." 
        ::= { dcxMACSpectralMgtActionEntry 1 }
    
    dcxMACSpMgtActionType OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Identifies the action type represented by this entry."
        ::= { dcxMACSpectralMgtActionEntry 2 }
    
    dcxMACSpMgtActionParam1 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "Parameter dependent on action type."
        ::= { dcxMACSpectralMgtActionEntry 3 }
    
    dcxMACSpMgtActionParam2 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "Parameter dependent on action type."
        ::= { dcxMACSpectralMgtActionEntry 4 }
    
    dcxMACSpMgtActionParam3 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "Parameter dependent on action type."
        ::= { dcxMACSpectralMgtActionEntry 5 }
    
    dcxMACSpMgtActionParam4 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "Parameter dependent on action type."
        ::= { dcxMACSpectralMgtActionEntry 6 }
    
    dcxMACSpMgtActionParam5 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "Parameter dependent on action type."
        ::= { dcxMACSpectralMgtActionEntry 7 }
    
    dcxMACSpMgtActionParam6 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "Parameter dependent on action type."
        ::= { dcxMACSpectralMgtActionEntry 8 }
    
    dcxMACSpMgtActionParam7 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "Parameter dependent on action type."
        ::= { dcxMACSpectralMgtActionEntry 9 }
    
    dcxMACSpMgtActionParam8 OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "Parameter dependent on action type."
        ::= { dcxMACSpectralMgtActionEntry 10 }
    
    dcxMACSpMgtActionStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
           "Used to create and control the status of entries in this table."
        ::= { dcxMACSpectralMgtActionEntry 11 }

-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --    
-- Shared Secret configuration
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --      

    dcxMACSharedSecretTable  OBJECT-TYPE        
        SYNTAX  SEQUENCE OF DcxMACSharedSecretEntry        
        MAX-ACCESS not-accessible        
        STATUS     current        
        DESCRIPTION                
            "Set up shared secrets for this DOCSIS MAC Interface"        
        ::= { dcxMACObjects 7 }    
    
    dcxMACSharedSecretEntry OBJECT-TYPE        
        SYNTAX DcxMACSharedSecretEntry        
        MAX-ACCESS  not-accessible        
        STATUS  current        
        DESCRIPTION             
            "dcxMACSharedSecretEntry"        
        INDEX {ifIndex, dcxMACSharedSecretId}        
        ::= { dcxMACSharedSecretTable 1 }    
        
    DcxMACSharedSecretEntry ::= SEQUENCE {        
        dcxMACSharedSecretId     Integer32,        
        dcxMACSharedSecretStr    DisplayString,        
        dcxMACSharedSecretStatus RowStatus            
        }    
    
    dcxMACSharedSecretId OBJECT-TYPE        
        SYNTAX      Integer32 (1..16)        
        MAX-ACCESS  not-accessible       
        STATUS      current        
        DESCRIPTION            
            "ID for the associated shared secret."        
        ::= { dcxMACSharedSecretEntry 1 }      
              
    dcxMACSharedSecretStr OBJECT-TYPE        
        SYNTAX      DisplayString        
        MAX-ACCESS  read-create        
        STATUS      current        
        DESCRIPTION            
            "This is the shared secret itself, which is considered write-only. It can be SET 
             but when a GET operation is performed the value is not returned."        
        ::= { dcxMACSharedSecretEntry 2 }            
    
    dcxMACSharedSecretStatus OBJECT-TYPE        
        SYNTAX      RowStatus        
        MAX-ACCESS  read-create        
        STATUS      current        
        DESCRIPTION            
            "Row status."        
        ::= { dcxMACSharedSecretEntry 3 }
    
END