-- Jacarta interSeptor MIB
-- MIB for interSeptor Environmental Monitoring System
--
-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) jacarta(19011)
-- product(1) webAppliance(3) inSept(1)
-- ==============================================================================================
---
---     Revision History
---
---	V1.00  - Initial Release - July 03
---	V1.01  - Minor SNMP bug fix - Aug 03
---	v1.10  - Add temperature unit object	- 	Oct, 15  2004	
---		 Add date format object	
---		 Add inSeptConfigAccessControlTable
---		 Add object  
---	v1.11	Change interSeptor-MIB to InterSeptor-MIB	-	Dec, 20 2004
---		Updated InSeptsensorConfigSensorEntry and SensorMonitorSensorEntry
--- V1.12  - Modified syntax error - May, 10 2005
---    		 Fixed SYNTAX InSeptConfigTrapsReceiversEntry
---			 Changed SYNTAX inSeptConfigTrapsReceiversEntry to SYNTAX InSeptConfigTrapsReceiversEntry
--- V1.13  - Modified syntax error - June, 27 2006 
---          Check error form http://wwwsnmp.cs.utwente.nl/ietf/mibs/validate/
--- ===========================================================================================
InterSeptor-MIB DEFINITIONS ::= BEGIN

IMPORTS
  enterprises
    FROM RFC1155-SMI
  OBJECT-TYPE
    FROM RFC-1212
  DisplayString
    FROM RFC1213-MIB
  TRAP-TYPE
    FROM RFC-1215;

jacarta         OBJECT IDENTIFIER ::= { enterprises 19011 }
product         OBJECT IDENTIFIER ::= { jacarta 1 }
webAppliance    OBJECT IDENTIFIER ::= { product 3 }
inSept          OBJECT IDENTIFIER ::= { webAppliance 1}
inSeptObjects   OBJECT IDENTIFIER ::= { inSept 1 }
inSeptTraps     OBJECT IDENTIFIER ::= { inSept 2 }

inSeptIdent   OBJECT IDENTIFIER ::= { inSeptObjects 1 }
inSeptConfig  OBJECT IDENTIFIER ::= { inSeptObjects 2 }
inSeptsensorMonitor   OBJECT IDENTIFIER ::= { inSeptObjects 3 }
inSeptsensorConfig    OBJECT IDENTIFIER ::= { inSeptObjects 4 }

-- ===========================================================================
--
-- inSeptIdentification
--
--     All objects in this group except for inSeptIdentName and
--     inSeptIdentAttachedDevices are set at device initialization
--     and remain static.
--
-- ===========================================================================

inSeptIdentManufacturer OBJECT-TYPE
       SYNTAX     DisplayString (SIZE (0..31))
       ACCESS read-only
       STATUS     mandatory
       DESCRIPTION
               "The name of the interSeptor manufacturer."
       ::= { inSeptIdent 1 }

inSeptIdentModel OBJECT-TYPE
      SYNTAX DisplayString (SIZE (0..63))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
          "The interSeptor Model designation."
      ::= { inSeptIdent 2 }

inSeptIdentAgentSoftwareVersion OBJECT-TYPE
      SYNTAX DisplayString (SIZE(0..31))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
               "The interSeptor software/firmware version."
      ::= { inSeptIdent 3 }

inSeptIdentName OBJECT-TYPE
       SYNTAX DisplayString (SIZE(0..31))
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
               "A string identifying the interSeptor.  This object should be
               set by the administrator."
       ::= { inSeptIdent 4 }

-- ===========================================================================
--
-- inSeptConfig
--
-- ===========================================================================

inSeptConfigMibVersion OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The version of MIB spec."
        ::= { inSeptConfig 1}

inSeptConfigNetwork   OBJECT IDENTIFIER ::= { inSeptConfig 2 }

inSeptConfigIpAddress OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                " The ip address that NMS can identify the managed
                device"
        ::= { inSeptConfigNetwork 1 }

inSeptConfigGateway OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                " The default gateway that allows the device to be managed
                through routers "
        ::= { inSeptConfigNetwork 2 }

inSeptConfigSubnetMask OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                " Internet address subnet mask"
        ::= { inSeptConfigNetwork 3 }

inSeptConfigDateTime   OBJECT IDENTIFIER ::= { inSeptConfig 3 }

inSeptConfigDate OBJECT-TYPE
        SYNTAX DisplayString (SIZE (10..10))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The date in inSept, format is (dd/mm/yyyy)"
        ::= { inSeptConfigDateTime 1}

inSeptConfigTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (8..8))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The time in interSeptor, format is (hh:mm:ss)"
        ::= { inSeptConfigDateTime 2}

inSeptConfigTimeFromNtp OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable update date/time from NTP server."
        ::= { inSeptConfigDateTime 3}

inSeptConfigNtpIpAddress OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "NTP IP address."
        ::= { inSeptConfigDateTime 4}

inSeptConfigNtpTimeZone OBJECT-TYPE
        SYNTAX INTEGER {
                gMT-1200(1),
                gMT-1100(2),
                gMT-1000(3),
                gMT-0900(4),
                gMT-0800(5),
                gMT-0700(6),
                gMT-0600(7),
                gMT-0500(8),
                gMT-0400(9),
                gMT-0330(10),
                gMT-0300(11),
                gMT-0200(12),
                gMT-0100(13),
                gMT-0000(14),
                gMT0100(15),
                gMT0200(16),
                gMT0300(17),
                gMT0330(18),
                gMT0400(19),
                gMT0500(20),
                gMT0530(21),
                gMT0600(22),
                gMT0700(23),
                gMT0800(24),
                gMT0900(25),
                gMT1000(26),
                gMT1100(27),
                gMT1200(28)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable update date/time from NTP server."
        ::= { inSeptConfigDateTime 5}

inSeptConfigDayLightSaving OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable daylight saving for NTP time, if enabled, the time get from NTP will be set
		 set one hour in advance to reflect daylight saving status."
        ::= { inSeptConfigDateTime 6}

inSeptConfigLog   OBJECT IDENTIFIER ::= { inSeptConfig 4 }

inSeptConfigHistoryLogFrequency OBJECT-TYPE
        SYNTAX INTEGER (5..3600) -- in seconds
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The frequency of the update of the history log. The value
                 is in seconds"
        ::= { inSeptConfigLog 1}

inSeptConfigExtHistoryLogFrequency      OBJECT-TYPE
        SYNTAX INTEGER (1..1440) -- in minutes
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The frequency of the update of the extended history log.
                 The value is in seconds"
        ::= { inSeptConfigLog 2}

inSeptConfigConfigurationLog OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                " Enable/disable inSept to log parameter change."
        ::= { inSeptConfigLog 3}

inSeptConfigDhcpStatue OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable DHCP/BootP capability"
        ::= { inSeptConfig 5}

inSeptConfigPingStatue OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable Ping Echo capability"
        ::= { inSeptConfig 6}

inSeptConfigTftpStatue OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable TFTP network upgrade capability"
        ::= { inSeptConfig 7}

inSeptConfigTelnet   OBJECT IDENTIFIER ::= { inSeptConfig 8 }

inSeptConfigTelnetStatue OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable telnet access"
        ::= { inSeptConfigTelnet 1}

inSeptConfigTelnetPortNumber            OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                 "Setting the server port of telnet."
        ::= { inSeptConfigTelnet 2}

inSeptConfigHttp   OBJECT IDENTIFIER ::= { inSeptConfig 9 }

inSeptConfigHttpStatue OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable HTTP access"
        ::= { inSeptConfigHttp 1}

inSeptConfigHttpPortNumber            OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                 "Setting the server port of HTTP."
        ::= { inSeptConfigHttp 2}

inSeptConfigHttpSecurity OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable HTTP access for read-only users"
        ::= { inSeptConfigHttp 3}


inSeptConfigSnmp   OBJECT IDENTIFIER ::= { inSeptConfig 10 }
inSeptConfigSnmpStatue OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable SNMP access"
        ::= { inSeptConfigSnmp 1}

inSeptConfigSnmpPortNumber            OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                 "Setting the server port of SNMP."
        ::= { inSeptConfigSnmp 2}

inSeptConfigControl   OBJECT IDENTIFIER ::= { inSeptConfig 11 }
inSeptConfigResetToDefault OBJECT-TYPE
        SYNTAX  INTEGER {
                reset(1),
                nothing(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Reset all parameters of interSeptor to default value"
        ::= { inSeptConfigControl 1}

inSeptConfigRestart OBJECT-TYPE
        SYNTAX  INTEGER {
                restart(1),
                nothing(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Restart interSeptor"
        ::= { inSeptConfigControl 2}

inSeptConfigTrap   OBJECT IDENTIFIER ::= { inSeptConfig 12 }
inSeptConfigTrapRetryCount OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The count of repeat traps to send to NMS before trap
                 acknowledgement is received."
        ::= { inSeptConfigTrap 1}

inSeptConfigTrapRetryTime OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The time between retrying to send traps to NMS."
        ::= { inSeptConfigTrap 2}

inSeptConfigTrapAckSignature OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The signature of trap acknowledgement."
        ::= { inSeptConfigTrap 3}


inSeptConfigPollRate OBJECT-TYPE
        SYNTAX INTEGER (3..60)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                " The frequency that interSeptor updates readings from sensors
                (unit : second)."
        ::= { inSeptConfig 13}

inSeptConfigTrapsReceiversTable OBJECT-TYPE
        SYNTAX SEQUENCE OF InSeptConfigTrapsReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of managers to send traps to.  The number of
                 entries is given by the value of inSeptConfigNumTrapReceivers"
        ::= { inSeptConfig 14}

inSeptConfigTrapsReceiversEntry OBJECT-TYPE
        SYNTAX InSeptConfigTrapsReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The managers to send traps to."
        INDEX  { inSepttrapsIndex}
        ::= { inSeptConfigTrapsReceiversTable 1 }

InSeptConfigTrapsReceiversEntry ::=
        SEQUENCE {
                inSepttrapsIndex
                        INTEGER,
                inSepttrapsReceiverAddr
                        IpAddress,
                inSeptreceiverCommunityString
                         DisplayString,
                inSeptreceiverSeverityLevel
                        INTEGER,
                inSeptreceiverDescription
                         DisplayString
        }        

inSepttrapsIndex OBJECT-TYPE
        SYNTAX INTEGER (1..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to a trap receiver entry."
        ::= { inSeptConfigTrapsReceiversEntry 1 }

inSepttrapsReceiverAddr OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The IP address of the manager to send a trap to."
        ::= { inSeptConfigTrapsReceiversEntry 2 }

inSeptreceiverCommunityString OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..19))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The community name to use in the trap when
                 sent to the manager."
        ::= { inSeptConfigTrapsReceiversEntry 3 }

inSeptreceiverSeverityLevel OBJECT-TYPE
        SYNTAX  INTEGER {
                informational(1),
                warning(2),
                severe(3)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The severity level of traps to be received by this manager."
        ::= { inSeptConfigTrapsReceiversEntry 4 }

inSeptreceiverDescription OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..31))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Description of trap receivers"
        ::= { inSeptConfigTrapsReceiversEntry 5 }

inSeptConfigAccessControlTable OBJECT-TYPE
        SYNTAX SEQUENCE OF InSeptConfigAccessControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of managers which can access interSeptor with private
                community string."
        ::= { inSeptConfig 15}

inSeptConfigAccessControlEntry OBJECT-TYPE
        SYNTAX InSeptConfigAccessControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The managers."
        INDEX  { accessIndex}
        ::= { inSeptConfigAccessControlTable 1 }

InSeptConfigAccessControlEntry ::=
        SEQUENCE {
                accessIndex
                        INTEGER,
                accessControlAddr
                        IpAddress,
                accessCommunityString
                         DisplayString,
                accessControlMode
                        INTEGER
        }

accessIndex OBJECT-TYPE
        SYNTAX INTEGER (1..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to a access control entry."
        ::= { inSeptConfigAccessControlEntry 1 }

accessControlAddr OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The IP address of the manager to access interSeptor"
        ::= { inSeptConfigAccessControlEntry 2 }

accessCommunityString OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..19))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The community name to use in the manager when
                 access interSeptor"
        ::= { inSeptConfigAccessControlEntry 3 }

accessControlMode OBJECT-TYPE
        SYNTAX  INTEGER {
                readOnly (1),
                read-write (2),
                notAccess (3)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Access type, only read/Write access type can change parameter
                 of interSeptor"
        ::= { inSeptConfigAccessControlEntry 4 }


inSeptConfigTemperatureUnit OBJECT-TYPE
        SYNTAX  INTEGER {
                celsius(1),
                fahrenheit(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The temperature unit of the system, can be Celsius or Farenheit"
        ::= { inSeptConfig 16}

inSeptConfigDateFormat OBJECT-TYPE
        SYNTAX  INTEGER {
                dd-mm-yyyy(1),
                mm-dd-yyyy(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The date format of the system, can be dd/mm/yyyy or mm/dd/yyyy"
        ::= { inSeptConfig 17}


-- Sensor Monitoring

inSeptsensorMonitorSensorNumber OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The number of sensors that can be monitored."
        ::= { inSeptsensorMonitor 1}

inSeptsensorMonitorSensorTable OBJECT-TYPE
        SYNTAX SEQUENCE OF SensorMonitorSensorEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of sensor devices to be monitored."
        ::= { inSeptsensorMonitor 2}

inSeptsensorMonitorSensorEntry OBJECT-TYPE
        SYNTAX SensorMonitorSensorEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The sensor device."
        INDEX  { inSeptsensorMonitorDeviceIndex}
        ::= { inSeptsensorMonitorSensorTable 1 }

SensorMonitorSensorEntry ::=
        SEQUENCE {
                inSeptsensorMonitorDeviceIndex
                        INTEGER,
                inSeptsensorMonitorDeviceStatus
                        INTEGER,
                inSeptsensorMonitorDeviceTemperature
                        INTEGER,
                inSeptsensorMonitorDeviceTemperatureAlarm
                        INTEGER,
                inSeptsensorMonitorDeviceHumidity
                        INTEGER,
                inSeptsensorMonitorDeviceHumidityAlarm
                        INTEGER,
                inSeptsensorMonitorAlarm1
                        INTEGER,
                inSeptsensorMonitorAlarm2
                        INTEGER
        }

inSeptsensorMonitorDeviceIndex OBJECT-TYPE
        SYNTAX INTEGER (1..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to a sensor device entry."
        ::= { inSeptsensorMonitorSensorEntry 1 }

inSeptsensorMonitorDeviceStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                unknown(1),
                disabled(2),
                eMD-HT(3),
                eMD-T(4)
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The device type connected to interSeptor."
        ::= { inSeptsensorMonitorSensorEntry 2 }

inSeptsensorMonitorDeviceTemperature OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The temperature of sensor on device interSeptor, the unit is 0.1 degree."
        ::= { inSeptsensorMonitorSensorEntry 3 }

inSeptsensorMonitorDeviceTemperatureAlarm OBJECT-TYPE
        SYNTAX  INTEGER {
                unknown(1),
                disabled(2),
                normal(3),
                lowWarning(4),
                lowCritical(5),
                highWarning(6),
                highCritical(7)
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The alarm type of sensor on device interSeptor."
        ::= { inSeptsensorMonitorSensorEntry 4 }

inSeptsensorMonitorDeviceHumidity OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The humidity of sensor on device interSeptor, the unit is 0.1%."
        ::= { inSeptsensorMonitorSensorEntry 5 }

inSeptsensorMonitorDeviceHumidityAlarm OBJECT-TYPE
        SYNTAX  INTEGER {
                unknown(1),
                disabled(2),
                normal(3),
                lowWarning(4),
                lowCritical(5),
                highWarning(6),
                highCritical(7)
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The alarm type of sensor on device interSeptor."
        ::= { inSeptsensorMonitorSensorEntry 6 }

inSeptsensorMonitorAlarm1 OBJECT-TYPE
        SYNTAX  INTEGER {
                unknown(1),
                disabled(2),
                active(3),
                inactive(4)
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The device status of sensor 1 connected to interSeptor."
        ::= { inSeptsensorMonitorSensorEntry 7 }

inSeptsensorMonitorAlarm2 OBJECT-TYPE
        SYNTAX  INTEGER {
                unknown(1),
                disabled(2),
                active(3),
                inactive(4)
                }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The device status of sensor 2 connected to interSeptor."
        ::= { inSeptsensorMonitorSensorEntry 8 }

-- Sensor Configuration

inSeptsensorConfigSensorNumber OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The number of sensors that are connected to interSeptor."
        ::= { inSeptsensorConfig 1 }

inSeptsensorConfigSensorTable OBJECT-TYPE
        SYNTAX SEQUENCE OF InSeptsensorConfigSensorEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of sensor devices to be configured."
        ::= { inSeptsensorConfig 2 }

inSeptsensorConfigSensorEntry OBJECT-TYPE
        SYNTAX InSeptsensorConfigSensorEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The sensor device."
        INDEX  { inSeptsensorConfigDeviceIndex }
        ::= { inSeptsensorConfigSensorTable 1 }

InSeptsensorConfigSensorEntry ::=
        SEQUENCE {
                inSeptsensorConfigDeviceIndex
                        INTEGER,
                inSeptsensorConfigDeviceName
                         DisplayString,
                inSeptsensorConfigDeviceState
                        INTEGER
        }

inSeptsensorConfigDeviceIndex OBJECT-TYPE
        SYNTAX INTEGER (1..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to a sensor device entry."
        ::= { inSeptsensorConfigSensorEntry 1 }

inSeptsensorConfigDeviceName OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name of the sensor device for identification."
        ::= { inSeptsensorConfigSensorEntry 2 }

inSeptsensorConfigDeviceState OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                auto(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The setup of sensor device type."
        ::= { inSeptsensorConfigSensorEntry 3 }

inSeptsensorConfigSensor1    OBJECT IDENTIFIER ::= { inSeptsensorConfig 3 }

inSeptsensorConfigSensor1DeviceName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name of sensor device."
        ::= { inSeptsensorConfigSensor1 1}

inSeptsensorConfigSensor1DeviceState OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                auto(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The setup of sensor device type."
        ::= { inSeptsensorConfigSensor1 2 }

inSeptsensorConfigSensor1Temperature    OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor1 3 }

inSeptsensorConfigSensor1TemperatureName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The temperature sensor name."
        ::= { inSeptsensorConfigSensor1Temperature 1 }

inSeptsensorConfigSensor1TemperatureLowWarning OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set point to trigger low warning alarm."
        ::= { inSeptsensorConfigSensor1Temperature 2 }


inSeptsensorConfigSensor1TemperatureLowCritical OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger low critical alarm."
        ::= { inSeptsensorConfigSensor1Temperature 3 }

inSeptsensorConfigSensor1TemperatureHighWarning OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger high warning alarm."
        ::= { inSeptsensorConfigSensor1Temperature 4 }

inSeptsensorConfigSensor1TemperatureHighCritical OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger high critical alarm."
        ::= { inSeptsensorConfigSensor1Temperature 5 }

inSeptsensorConfigSensor1TemperatureHysteresis OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to prevent too many alarms when temperature is hovering around the
                 set threshold."
        ::= { inSeptsensorConfigSensor1Temperature 6 }

inSeptsensorConfigSensor1TemperatureCalibration OBJECT-TYPE
        SYNTAX INTEGER {
                temperatureIncrease0Point0(1),
                temperatureIncrease0Point5(2),
                temperatureIncrease1Point0(3),
                temperatureIncrease1Point5(4),
                temperatureIncrease2Point0(5),
                temperatureIncrease2Point5(6),
                temperatureIncrease3Point0(7),
                temperatureMinus0Point5(8),
                temperatureMinus1Point0(9),
                temperatureMinus1Point5(10),
                temperatureMinus2Point0(11),
                temperatureMinus2Point5(12),
                temperatureMinusPoint0(13)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to get the correct temperature according to your reference temperature."
        ::= { inSeptsensorConfigSensor1Temperature 7 }

inSeptsensorConfigSensor1TemperatureLowWarningStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger low warning alarm."
        ::= { inSeptsensorConfigSensor1Temperature 8 }

inSeptsensorConfigSensor1TemperatureLowCriticalStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger low critical alarm."
        ::= { inSeptsensorConfigSensor1Temperature 9 }

inSeptsensorConfigSensor1TemperatureHighWarningStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger high warning alarm."
        ::= { inSeptsensorConfigSensor1Temperature 10 }

inSeptsensorConfigSensor1TemperatureHighCriticalStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger high critical alarm."
        ::= { inSeptsensorConfigSensor1Temperature 11 }

inSeptsensorConfigSensor1Humidity    OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor1 4 }

inSeptsensorConfigSensor1HumdityName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The humidity sensor name."
        ::= { inSeptsensorConfigSensor1Humidity 1 }

inSeptsensorConfigSensor1HumidityLowWarning OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set point to trigger low warning alarm."
        ::= { inSeptsensorConfigSensor1Humidity 2 }


inSeptsensorConfigSensor1HumidityLowCritical OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshole to trigger low critical alarm."
        ::= { inSeptsensorConfigSensor1Humidity 3 }

inSeptsensorConfigSensor1HumidityHighWarning OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger high warning alarm."
        ::= { inSeptsensorConfigSensor1Humidity 4 }

inSeptsensorConfigSensor1HumidityHighCritical OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger high critical alarm."
        ::= { inSeptsensorConfigSensor1Humidity 5 }

inSeptsensorConfigSensor1HumidityHysteresis OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to prevent too many alarms when Humidity is hovering around the
                 set threshold."
        ::= { inSeptsensorConfigSensor1Humidity 6 }

inSeptsensorConfigSensor1HumidityCalibration OBJECT-TYPE
        SYNTAX INTEGER {                
                humidityIncrease0Point0(1),
                humidityIncrease1Point0(2),
                humidityIncrease2Point0(3),
                humidityIncrease3Point0(4),
                humidityIncrease4Point0(5),
                humidityIncrease5Point0(6),
                humidityIncrease6Point0(7),
                humidityMinus1Point0(8),
                humidityMinus2Point0(9),
                humidityMinus3Point0(10),
                humidityMinus4Point0(11),
                humidityMinus5Point0(12),
                humidityMinus6Point0(13)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to get the correct temperature according to your reference temperature."
        ::= { inSeptsensorConfigSensor1Humidity 7 }

inSeptsensorConfigSensor1HumidityLowWarningStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger low warning alarm."
        ::= { inSeptsensorConfigSensor1Humidity 8 }

inSeptsensorConfigSensor1HumidityLowCriticalStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger low critical alarm."
        ::= { inSeptsensorConfigSensor1Humidity 9 }

inSeptsensorConfigSensor1HumidityHighWarningStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger high warning alarm."
        ::= { inSeptsensorConfigSensor1Humidity 10 }

inSeptsensorConfigSensor1HumidityHighCriticalStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger high critical alarm."
        ::= { inSeptsensorConfigSensor1Humidity 11 }

inSeptsensorConfigSensor1Alarm1    OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor1 5 }

inSeptsensorConfigSensor1Alarm1Name OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name of alarm-1."
        ::= { inSeptsensorConfigSensor1Alarm1 1 }

inSeptsensorConfigSensor1Alarm1State OBJECT-TYPE
        SYNTAX INTEGER {
                disabled(1),
                normalOpen(2),
                normalClose(3),
                highActive(4),
                lowActive(5)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setup the signal type to trigger alarm."
        ::= { inSeptsensorConfigSensor1Alarm1 2 }

inSeptsensorConfigSensor1Alarm1Hysteresis OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to delay the alarm triggered when event occurs."
        ::= { inSeptsensorConfigSensor1Alarm1 3 }

inSeptsensorConfigSensor1Alarm2    OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor1 6 }

inSeptsensorConfigSensor1Alarm2Name OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name of alarm-1."
        ::= { inSeptsensorConfigSensor1Alarm2 1 }

inSeptsensorConfigSensor1Alarm2State OBJECT-TYPE
        SYNTAX INTEGER {
                disabled(1),
                normalOpen(2),
                normalClose(3),
                highActive(4),
                lowActive(5)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setup the signal type to trigger alarm."
        ::= { inSeptsensorConfigSensor1Alarm2 2 }

inSeptsensorConfigSensor1Alarm2Hysteresis OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to delay the alarm triggered when event occurs."
        ::= { inSeptsensorConfigSensor1Alarm2 3 }

inSeptsensorConfigSensor2    OBJECT IDENTIFIER ::= { inSeptsensorConfig 4 }

inSeptsensorConfigSensor2DeviceName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name of sensor device."
        ::= { inSeptsensorConfigSensor2 1}

inSeptsensorConfigSensor2DeviceState OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                auto(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The setup of sensor device type."
        ::= { inSeptsensorConfigSensor2 2 }

inSeptsensorConfigSensor2Temperature    OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor2 3 }

inSeptsensorConfigSensor2TemperatureName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The temperature sensor name."
        ::= { inSeptsensorConfigSensor2Temperature 1 }

inSeptsensorConfigSensor2TemperatureLowWarning OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set point to trigger low warning alarm."
        ::= { inSeptsensorConfigSensor2Temperature 2 }


inSeptsensorConfigSensor2TemperatureLowCritical OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger low critical alarm."
        ::= { inSeptsensorConfigSensor2Temperature 3 }

inSeptsensorConfigSensor2TemperatureHighWarning OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger high warning alarm."
        ::= { inSeptsensorConfigSensor2Temperature 4 }

inSeptsensorConfigSensor2TemperatureHighCritical OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger high critical alarm."
        ::= { inSeptsensorConfigSensor2Temperature 5 }

inSeptsensorConfigSensor2TemperatureHysteresis OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to prevent too many alarms when temperature is hovering around the
                 set threshold."
        ::= { inSeptsensorConfigSensor2Temperature 6 }

inSeptsensorConfigSensor2TemperatureCalibration OBJECT-TYPE
        SYNTAX INTEGER {                                                
                temperatureIncrease0Point0(1),
                temperatureIncrease0Point5(2),
                temperatureIncrease1Point0(3),
                temperatureIncrease1Point5(4),
                temperatureIncrease2Point0(5),
                temperatureIncrease2Point5(6),
                temperatureIncrease3Point0(7),
                temperatureMinus0Point5(8),
                temperatureMinus1Point0(9),
                temperatureMinus1Point5(10),
                temperatureMinus2Point0(11),
                temperatureMinus2Point5(12),
                temperatureMinusPoint0(13)
        }        
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to get the correct temperature according to your reference temperature."
        ::= { inSeptsensorConfigSensor2Temperature 7 }

inSeptsensorConfigSensor2TemperatureLowWarningStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger low warning alarm."
        ::= { inSeptsensorConfigSensor2Temperature 8 }

inSeptsensorConfigSensor2TemperatureLowCriticalStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger low critical alarm."
        ::= { inSeptsensorConfigSensor2Temperature 9 }

inSeptsensorConfigSensor2TemperatureHighWarningStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger high warning alarm."
        ::= { inSeptsensorConfigSensor2Temperature 10 }

inSeptsensorConfigSensor2TemperatureHighCriticalStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger high critical alarm."
        ::= { inSeptsensorConfigSensor2Temperature 11 }

inSeptsensorConfigSensor2Humidity    OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor2 4 }

inSeptsensorConfigSensor2HumdityName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The humidity sensor name."
        ::= { inSeptsensorConfigSensor2Humidity 1 }

inSeptsensorConfigSensor2HumidityLowWarning OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set point to trigger low warning alarm."
        ::= { inSeptsensorConfigSensor2Humidity 2 }


inSeptsensorConfigSensor2HumidityLowCritical OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger low critical alarm."
        ::= { inSeptsensorConfigSensor2Humidity 3 }

inSeptsensorConfigSensor2HumidityHighWarning OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger high warning alarm."
        ::= { inSeptsensorConfigSensor2Humidity 4 }

inSeptsensorConfigSensor2HumidityHighCritical OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The threshold to trigger high critical alarm."
        ::= { inSeptsensorConfigSensor2Humidity 5 }

inSeptsensorConfigSensor2HumidityHysteresis OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to prevent too many alarms when Humidity is hovering around the
                 set threshold."
        ::= { inSeptsensorConfigSensor2Humidity 6 }

inSeptsensorConfigSensor2HumidityCalibration OBJECT-TYPE
        SYNTAX INTEGER {                                                                                                
                humidityIncrease0Point0(1),
                humidityIncrease1Point0(2),
                humidityIncrease2Point0(3),
                humidityIncrease3Point0(4),
                humidityIncrease4Point0(5),
                humidityIncrease5Point0(6),
                humidityIncrease6Point0(7),
                humidityMinus1Point0(8),
                humidityMinus2Point0(9),
                humidityMinus3Point0(10),
                humidityMinus4Point0(11),
                humidityMinus5Point0(12),
                humidityMinus6Point0(13)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to get the correct temperature according to your reference temperature."
        ::= { inSeptsensorConfigSensor2Humidity 7 }

inSeptsensorConfigSensor2HumidityLowWarningStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger low warning alarm."
        ::= { inSeptsensorConfigSensor2Humidity 8 }

inSeptsensorConfigSensor2HumidityLowCriticalStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger low critical alarm."
        ::= { inSeptsensorConfigSensor2Humidity 9 }

inSeptsensorConfigSensor2HumidityHighWarningStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger high warning alarm."
        ::= { inSeptsensorConfigSensor2Humidity 10 }

inSeptsensorConfigSensor2HumidityHighCriticalStatus OBJECT-TYPE
        SYNTAX INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable/disable the set point to trigger high critical alarm."
        ::= { inSeptsensorConfigSensor2Humidity 11 }

inSeptsensorConfigSensor2Alarm1    OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor2 5 }

inSeptsensorConfigSensor2Alarm1Name OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name of alarm-1."
        ::= { inSeptsensorConfigSensor2Alarm1 1 }

inSeptsensorConfigSensor2Alarm1State OBJECT-TYPE
        SYNTAX INTEGER {
                disabled(1),
                normalOpen(2),
                normalClose(3),
                highActive(4),
                lowActive(5)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setup the signal type to trigger alarm."
        ::= { inSeptsensorConfigSensor2Alarm1 2 }

inSeptsensorConfigSensor2Alarm1Hysteresis OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to delay the alarm triggered when event occurs."
        ::= { inSeptsensorConfigSensor2Alarm1 3 }

inSeptsensorConfigSensor2Alarm2    OBJECT IDENTIFIER ::= { inSeptsensorConfigSensor2 6 }

inSeptsensorConfigSensor2Alarm2Name OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The name of alarm-1."
        ::= { inSeptsensorConfigSensor2Alarm2 1 }

inSeptsensorConfigSensor2Alarm2State OBJECT-TYPE
        SYNTAX INTEGER {
                disabled(1),
                normalOpen(2),
                normalClose(3),
                highActive(4),
                lowActive(5)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Setup the signal type to trigger alarm."
        ::= { inSeptsensorConfigSensor2Alarm2 2 }

inSeptsensorConfigSensor2Alarm2Hysteresis OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The set value to delay the alarm triggered when event occurs."
        ::= { inSeptsensorConfigSensor2Alarm2 3 }


-- ===========================================================================
-- inSeptTraps
--
-- Traps group
-- ===========================================================================
-- This section defines the well-known notifications sent by
-- inSept agents.
-- Care must be taken to ensure that no particular notification
-- is sent to a single receiving entity more often than once
-- every five seconds.

inSeptCommunicationRestored TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: Communication between interSeptor and sensor has been
                 established."
        ::= 1

inSeptCommunicationLost TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "WARNING: Communication between interSeptor and sensor has been
                 lost."
        ::= 2

inSeptAlarm1Inactive TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: Alarm1 of sensor has returned from active state."
        ::= 3

inSeptAlarm1Active TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "WARNING: Alarm1 has become active."
        ::= 4

inSeptAlarm2Inactive TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: Alarm2 of sensor has returned from active state."
        ::= 5

inSeptAlarm2Active TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "WARNING: Alarm2 has become active."
        ::= 6

inSeptTemperatureNotHighWarning TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: The temperature of sensor has returned from High warning to normal."
        ::= 7

inSeptTemperatureHighWarning TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "WARNING: The temperature of sensor is higher than High warning set point."
        ::= 8

inSeptTemperatureNotLowWarning TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: The temperature of sensor has returned from low warning to normal."
        ::= 9

inSeptTemperatureLowWarning TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "WARNING: The temperature of sensor is lower than low warning set point."
        ::= 10

inSeptTemperatureNotHighCritical TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: The temperature of sensor is lower than high critical set point."
        ::= 11

inSeptTemperatureHighCritical TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "CRITICAL: The temperature of sensor is higher than high critical set point."
        ::= 12

inSeptTemperatureNotLowCritical TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: The temperature of sensor is higher than low critical set point."
        ::= 13

inSeptTemperatureLowCritical TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "CRITICAL: The temperature of sensor is lower than low critical set point."
        ::= 14

inSeptHumidityNotHighWarning TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: The humidity of sensor has returned from High warning to normal."
        ::= 15

inSeptHumidityHighWarning TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "WARNING: The humidity of sensor is higher than High warning set point."
        ::= 16

inSeptHumidityNotLowWarning TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: The humidity of sensor has returned from low warning to normal."
        ::= 17

inSeptHumidityLowWarning TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "WARNING: The humidity of sensor is lower than low warning set point."
        ::= 18

inSeptHumidityNotHighCritical TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: The humidity of sensor is lower than high critical set point."
        ::= 19

inSeptHumidityHighCritical TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "CRITICAL: The humidity of sensor is higher than high critical set point."
        ::= 20

inSeptHumidityNotLowCritical TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "INFORMATION: The humidity of sensor is higher than low critical set point."
        ::= 21

inSeptHumidityLowCritical TRAP-TYPE
        ENTERPRISE inSeptTraps
        DESCRIPTION
                "CRITICAL: The humidity of sensor is lower than low critical set point."
        ::= 22

END