ACCOUNTING-MIB DEFINITIONS ::= BEGIN

IMPORTS
    experimental, Counter, TimeTicks, Opaque FROM RFC1155-SMI
    OBJECT-TYPE FROM RFC-1212
    mib-2 FROM RFC1213-MIB;

acctMIB OBJECT IDENTIFIER ::= { mib-2 40 }

acctControl     OBJECT IDENTIFIER ::= { acctMIB 1 }

acctFlowdata    OBJECT IDENTIFIER ::= { acctMIB 2 }

acctRuledata    OBJECT IDENTIFIER ::= { acctMIB 3 }


-- The AddressTuple construct:
-- In future might have any address for any layer in the protocol stack
-- (session, presentation, transport, application).  The intent here is
-- to represent the fact that the address tuple field can contain many
-- attributes.

-- AddressTuple ::= SEQUENCE {
--    interface           [ 0] INTEGER OPTIONAL,

--    adjacent_type       [ 1] AddressType OPTIONAL,
--    adjacent_address    [ 2] NetWorkAddress OPTIONAL,
--    adjacent_mask       [ 3] NetWorkAddress OPTIONAL,

--    peer_type           [ 4] AddressType OPTIONAL,
--    peer_address        [ 5] NetWorkAddress OPTIONAL,
--    peer_mask           [ 6] NetWorkAddress OPTIONAL,

--    transport_type      [ 7] AddressType OPTIONAL,
--    transpoprt_address  [ 8] NetWorkAddress OPTIONAL,
--    transport_mask      [ 9] NetWorkAddress OPTIONAL,
--    }

-- Within an address tuple the mask attributes are used to specify
-- which parts of the addresses must match exactly when address tuples
-- are compared.  For example peer type = ipaddress, peer address =
-- 130.216.0.0, peer mask = 255.255.0.0 would match any peer address
-- representing an IP interface within network 130.216.

-- As an example of types and values, here is an address tuple for a
-- flow carrying a stream of SMTP data over an ethernet:
--    adjacent type = ethernet,  adjacent address = 02-07-01-04-ED-4A
--    peer type = IP, peer address = 130.216.240.7
--    transport type = TCP, transport address = 25 (port number)

-- The Network Address construct:
-- The intent here is that this address type represent a choice of N-1
-- layer addresses based on the protocol layer at which accounting is
-- done.  For example, if accounting is being performed at the
-- presentation level, then this address might be a session layer
-- address; if done at the network level it might be an IP address.
-- The level at which accounting is done is the "peer" level, N.

-- In the following, "adjacent" means the level below the current level
-- and "transport" means the level above it.  For IP the adjacent layer
-- address might be the ethernet or 802 MAC layer address and the
-- transport address might be the IP port number.  A better encoding
-- convention may be needed so that addresses at any layer can be
-- specified unambiguously.

-- NetWorkAddress ::= CHOICE {
--    adjacentLayerAddress  [1] IMPLICIT OCTET STRING,

--    ipAddress             [2] IMPLICIT IpAddress,
--    nsapAddress           [3] IMPLICIT OCTET STRING,
--    idprAddress           [4] IMPLICIT OCTET STRING,
--    decnetAddress         [5] IMPLICIT OCTET STRING,
--    ipxnetAddress         [6] IMPLICIT OCTET STRING,
--    ethertalkAddress      [7] IMPLICIT OCTET STRING,

--    transportAddress      [8] IMPLICIT OCTET STRING
--    }

-- The AddressType type:
-- The intent of this type is to indicate the type of address
-- that is being recorded.  This would probably be encoded as a
-- tag in the above NetworkAddress type if using full ASN.1.  Instead
-- we explicitly call it out as a separate value, and instantiate it
-- as a separate field.

AddressType ::= INTEGER {
        adjacentlayer(1), ipaddress(2), nsapaddress(3),
        idpraddress(4), decnetaddress(5),
        ipxnetaddress(6), ethertalkaddress(7),
        transportaddress(8)
        }


--
-- The Control Group
--

acctRuleSetInfoTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AcctRuleSetInfoEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Array of information about the rule sets held in the meter.
        Rule set 1 is the meter default, used when the meter starts
        up.  It may not be overwritten."
    ::= { acctControl 1 }

acctRuleSetInfoEntry OBJECT-TYPE
    SYNTAX  AcctRuleSetInfoEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Information about a particular rule set."
    INDEX  { acctRuleInfoIndex }
    ::= { acctRuleSetInfoTable 1 }

AcctRuleSetInfoEntry ::= SEQUENCE {
    acctRuleInfoIndex                   INTEGER (1..65535),
    acctRuleInfoRuleSize                INTEGER,
    acctRuleInfoActionSize              INTEGER
    }

acctRuleInfoIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Selects an entry from the array of rule set info entries."
    ::= { acctRuleSetInfoEntry 1 }

acctRuleInfoRuleSize OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Number of rules in this table.  Setting this variable will
        cause the meter to allocate space for these rules."
    ::= { acctRuleSetInfoEntry 2 }

acctRuleInfoActionSize OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Number of actions in this table.  Setting this variable will
        cause the meter to allocate space for these actions, and will
        set the values of all variables in them to zero."
    ::= { acctRuleSetInfoEntry 3 }

acctFlowSamplingTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AcctFlowSamplingEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Table of sampling rates for each interface."
    ::= { acctControl 2 }

acctFlowSamplingEntry OBJECT-TYPE
    SYNTAX  AcctFlowSamplingEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Defines the sampling rate for a particular interface."
    INDEX   { acctFlowSamplingIndex }
    ::= { acctFlowSamplingTable 1 }

AcctFlowSamplingEntry ::= SEQUENCE {
    acctFlowSamplingIndex     INTEGER,
    acctFlowSamplingRate      INTEGER
    }

acctFlowSamplingIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Identifies the interface for this sampling rate."
    ::= { acctFlowSamplingEntry 1 }

acctFlowSamplingRate OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "One for each interface.  The parameter N for statistical
        counting.  Set to N to count 1/Nth of the packets from this
        interface.  A meter should choose its own algorithm to
        introduce variance into the sampling so that exactly every Nth
        packet is not counted.  A sampling rate of 1 yields a normal
        counter.  A sampling rate of 0 results in the interface
        being ignored by the meter."
    DEFVAL { 1 } -- Count every packet,
    ::= { acctFlowSamplingEntry 2 }

acctCurrentRuleSet OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Index to the arrays of rule and action tables.  Specifies
        which set of rules and actions is currently being used for
        accounting by the meter.  When the manager sets this variable
        the meter will close its current rule set and start using the
        new one.  Flows created by the old rule set remain in memory,
        orphaned until their data has been collected."
    ::= { acctControl 3 }

acctEmergencyRuleSet OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Index to the arrays of rule and action tables.  After reaching
        HighWaterMark (see below) the meter may switch to using it's
        emergency rule set.  For this to be effective the manager should
        have downloaded an emergency rule set which uses a coarser
        collecting granularity.  The manager may also need to decrease
        the collecting interval so that the meter can recover flows
        from its normal rule set."
    ::= { acctControl 4 }

acctHighWaterMark OBJECT-TYPE
    SYNTAX  INTEGER (0..100)
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "A value expressed as a percentage, interpreted by the meter
        as an indication of how full the flow table should be before
        it should switch to the emergency rule set (if one has been
        specified).  Values of 0% or 100% disable the checking
        represented by this variable."
    ::= { acctControl 5 }

acctFloodMark OBJECT-TYPE
    SYNTAX  INTEGER (0..100)
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "A value expressed as a percentage, interpreted by the meter
        as an indication of how full the flow table should be before
        it should take some action to avoid running out of resources
        to handle new flows.  Values of 0% or 100% disable the
        checking represented by this variable."
    ::= { acctControl 6 }

acctCollectorInfoTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AcctCollectorInfoEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Information about snmp peers which have collected flow data
        from this meter."
    ::= { acctControl 7 }

acctCollectorInfoEntry OBJECT-TYPE
    SYNTAX  AcctCollectorInfoEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Information about a particular collector."
    INDEX  { acctCollectorIndex }
    ::= { acctCollectorInfoTable 1 }

AcctCollectorInfoEntry ::= SEQUENCE {
    acctCollectorIndex                  INTEGER (1..255),
    acctCollectorPeerAddress            OCTET STRING,
    acctCollectorLastTime               TimeTicks,
    acctCollectorPreviousTime           TimeTicks
    }

acctCollectorIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..255)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Selects an entry from the array of collector info entries."
    ::= { acctCollectorInfoEntry 1 }

acctCollectorPeerAddress OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Peer address of this collector."
    ::= { acctCollectorInfoEntry 2 }

acctCollectorLastTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Time this collector last began a collection."
    ::= { acctCollectorInfoEntry 3 }

acctCollectorPreviousTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Time this collector began the collection before last."
    ::= { acctCollectorInfoEntry 4 }

acctLastCollectTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Time last collection of meter data began.  This variable
        will be written by a collector as the first step in making a
        collection.  The meter will set its LastTime value to uptime
        and set its PreviousTime value to the old LastTime.  This
        allows the meter to recover flows which have been inactive
        since PreviousTime, for these have been collected at least
        once.  If the meter fails to write acctLastCollectTime, e.g.
        by failing authentication in the meter SNMP write community,
        collection may still proceed but the meter may not be able to
        recover inactive flows."
    ::= { acctControl 8 }

acctInactivityTimeout OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "The time in seconds since the last packet seen (and the
        last report) after which the flow may be terminated."
    DEFVAL { 600 } -- 10 minutes
    ::= { acctControl 9 }

acctActiveFlows OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The numbers of flows which are currently active, i.e. have
        been active since the last collection."
    ::= { acctControl 10 }

acctMaxFlows OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The maximum number of flows allowed in the meter's
        flow table."
    ::= { acctControl 11 }


--
-- The Flow Table
--

-- This is a table kept by a meter, with one entry for every flow
-- currently being accounted for.

-- The variables kept for each flow comprise:
--      Housekeeping information for the flow.
--      The flow's "counters", i.e. its octet and PDU counts for each
--              direction and its first and last packet times.
--      The flow's "keys", i.e. the information used to distinguish
--              packets for this particular flow.

-- Each flow has at least one key, but "aggregate" flows may have more
-- than one key.  Every key is associated with a single flow, and every
-- PDU matching a key is counted in its associated flow's counters.

-- Each packet which arrives at a meter is examined, and values for all
-- the "key" variables are extracted and assembled into a "packet key".
-- The set of current keys is searched to see whether this flow has
-- already been seen.  If it has, the packet is simply counted;
-- if not, the rules are consulted to create a new flow in which this
-- packet may be counted.  Once a flow has been created in this way a
-- collector will have to read the flow's key data just once.  After
-- that the collector needs only to read the flow's counts from time to
-- time.

-- Each key has two AddressTuples, one for each of its end points.
-- Flows are bidirectional and have two sets of counters, one for each
-- of the two possible directions.  Since we may be accounting for
-- packets observed in transit along a network segment the choice of
-- "to" and "from" direction is arbitrary; "source" and "destination"
-- (abbreviated to "dest" elsewhere in this MIB) are specified for each
-- flow by the rules in the current rule set.  In the special case
-- where the address tuples are identical all packets are counted in
-- the "to" direction's counters.

-- From time to time a collector may sweep the flow table so as collect
-- counts.  To reduce the number of SNMP requests required to do this,
-- two further tables provide alternative windows into the flow table.
-- The Creation Table allows a collector to find the first entry created
-- after a specified time, then make successive getnext requests to find
-- all other entries created since that time.  Similarly, the Activity
-- Table allows a collector to find all the entries last counted after
-- a specified time.  Note that it is not sensible for the meter to
-- keep the Activity Table in LastTime order, since that would result
-- in very active flows being counted many times during the same
-- collection.

-- This scheme allows multiple collectors to independently use the same
-- meter; the collectors do not have to be synchronised and they may
-- use different collection intervals.

-- A meter may reclaim the memory space used by flows (or keys) for
-- which no packets have been seen since lastCollectTime, or for an
-- interval longer than the inactivityTimeout, whichever is the longer.
-- The meter may reuse flow indexes for flows thus reclaimed.

acctFlowTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AcctFlowEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "The list of all flows being kept for accounting purposes
        on this system."
    ::= { acctFlowdata 1 }

acctFlowEntry OBJECT-TYPE
    SYNTAX  AcctFlowEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "The flow record for a particular flow."
    INDEX { acctFlowIndex }
    ::= { acctFlowTable 1 }

AcctFlowEntry ::= SEQUENCE {
    acctFlowIndex                   INTEGER (1..65535),
    acctFlowStatus                  INTEGER,

    acctFlowSourceInterface         INTEGER,    -- Source Address Tuple
    acctFlowSourceAdjacentType      AddressType,
    acctFlowSourceAdjacentAddress   OCTET STRING,
    acctFlowSourceAdjacentMask      OCTET STRING,
    acctFlowSourcePeerType          AddressType,
    acctFlowSourcePeerAddress       OCTET STRING,
    acctFlowSourcePeerMask          OCTET STRING,
    acctFlowSourceTransType         AddressType,
    acctFlowSourceTransAddress      OCTET STRING,
    acctFlowSourceTransMask         OCTET STRING,

    acctFlowDestInterface           INTEGER,    -- Dest Address Tuple
    acctFlowDestAdjacentType        AddressType,
    acctFlowDestAdjacentAddress     OCTET STRING,
    acctFlowDestAdjacentMask        OCTET STRING,
    acctFlowDestPeerType            AddressType,
    acctFlowDestPeerAddress         OCTET STRING,
    acctFlowDestPeerMask            OCTET STRING,
    acctFlowDestTransType           AddressType,
    acctFlowDestTransAddress        OCTET STRING,
    acctFlowDestTransMask           OCTET STRING,

    acctFlowPDUScale                INTEGER,    -- Rule Set attributes
    acctFlowOctetScale              INTEGER,
    acctFlowRuleSet                 INTEGER,

    acctFlowToOctets                Counter, -- Source-to-Dest counters
    acctFlowToPDUs                  Counter,
    acctFlowFromOctets              Counter, -- Dest-to-Source counters
    acctFlowFromPDUs                Counter,
    acctFlowFirstTime               TimeTicks,  -- Activity times
    acctFlowLastTime                TimeTicks,

    acctFlowSourceSubscriberID      OCTET STRING, -- Session attributes
    acctFlowDestSubscriberID        OCTET STRING,
    acctFlowSessionID               OCTET STRING,

    acctFlowSourceClass             INTEGER (1..255),
    acctFlowDestClass               INTEGER (1..255),     
    acctFlowClass                   INTEGER (1..255),
    acctFlowSourceKind              INTEGER (1..255),
    acctFlowDestKind                INTEGER (1..255),
    acctFlowKind                    INTEGER (1..255)
    }

acctFlowIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The bucket number for this flow.  The different values for
        this variable need not be consecutive.  Flow 1 is never used
        by the meter for a real flow.  Instead it is used as an initial
        value for SNMP getnext requests when scanning the flow table."
    ::= { acctFlowEntry 1 }

acctFlowStatus OBJECT-TYPE
    SYNTAX  INTEGER { valid(1), invalid(2) }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Status of this flow.  Allows all table rows to be collected
        via a simple table sweep, whilst throwing out all flows that
        are invalid."
    ::= { acctFlowEntry 2 }

acctFlowSourceInterface OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Index of the interface associated with the source address for
        this flow.  This value is one of the values contained in the
        ifIndex field of the interfaces table."
    ::= { acctFlowEntry 3 }

acctFlowSourceAdjacentType OBJECT-TYPE
    SYNTAX  AddressType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Adjacent address type of the source for this flow."
    ::= { acctFlowEntry 4 }

acctFlowSourceAdjacentAddress OBJECT-TYPE
    SYNTAX  OCTET STRING -- actually NetworkAddress
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Address of the adjacent device on the path for the source
        for this flow."
    ::= { acctFlowEntry 5 }

acctFlowSourceAdjacentMask OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "1-bits in this mask indicate which bits must match when
        comparing the adjacent source address for this flow."
    ::= { acctFlowEntry 6 }

acctFlowSourcePeerType OBJECT-TYPE
    SYNTAX  AddressType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Peer address type of the source for this flow."
    ::= { acctFlowEntry 7 }

acctFlowSourcePeerAddress OBJECT-TYPE
    SYNTAX  OCTET STRING -- actually NetworkAddress
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Address of the peer device for the source of this flow."
    ::= { acctFlowEntry 8 }

acctFlowSourcePeerMask OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "1-bits in this mask indicate which bits must match when
        comparing the source peer address for this flow."
    ::= { acctFlowEntry 9 }

acctFlowSourceTransType OBJECT-TYPE
    SYNTAX  AddressType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Transport address type of the source for this flow."
    ::= { acctFlowEntry 10 }

acctFlowSourceTransAddress OBJECT-TYPE
    SYNTAX  OCTET STRING -- actually NetworkAddress
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Transport address for the source of this flow."
    ::= { acctFlowEntry 11 }

acctFlowSourceTransMask OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "1-bits in this mask indicate which bits must match when
        comparing the transport source address for this flow."
    ::= { acctFlowEntry 12 }

acctFlowDestInterface OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Index of the interface associated with the dest address for
        this flow.  This value is one of the values contained in the
        ifIndex field of the interfaces table."
    ::= { acctFlowEntry 13 }

acctFlowDestAdjacentType OBJECT-TYPE
    SYNTAX  AddressType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Adjacent address type of the destination for this flow."
    ::= { acctFlowEntry 14 }

acctFlowDestAdjacentAddress OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Address of the adjacent device on the path for the
        destination for this flow."
    ::= { acctFlowEntry 15 }

acctFlowDestAdjacentMask OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "1-bits in this mask indicate which bits must match when
        comparing the adjacent dest address for this flow."
    ::= { acctFlowEntry 16 }

acctFlowDestPeerType OBJECT-TYPE
    SYNTAX  AddressType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Peer address type of the destination for this flow."
    ::= { acctFlowEntry 17 }

acctFlowDestPeerAddress OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Address of the peer device for the destination of this flow."
    ::= { acctFlowEntry 18 }

acctFlowDestPeerMask OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "1-bits in this mask indicate which bits must match when
        comparing the dest peer type for this flow."
    ::= { acctFlowEntry 19 }

acctFlowDestTransType OBJECT-TYPE
    SYNTAX  AddressType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Transport address type for the destination of this flow."
    ::= { acctFlowEntry 20 }

acctFlowDestTransAddress OBJECT-TYPE
    SYNTAX  OCTET STRING -- actually NetworkAddress
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Transport address for the destination of this flow."
    ::= { acctFlowEntry 21 }

acctFlowDestTransMask OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "1-bits in this mask indicate which bits must match when
        comparing the transport destination address for this flow."
    ::= { acctFlowEntry 22 }

acctFlowPDUScale OBJECT-TYPE
    SYNTAX  INTEGER (1..127)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The scale factor applied to this particular flow.  Indicates
        the number of bits the PDU counter values should be moved left
        to obtain the actual values."
    ::= { acctFlowEntry 23 }

acctFlowOctetScale OBJECT-TYPE
    SYNTAX  INTEGER (1..127)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The scale factor applied to this particular flow.  Indicates
        the number of bits the octet counter values should be moved
        left to obtain the actual values."
    ::= { acctFlowEntry 24 }

acctFlowRuleSet OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The RuleSet number of the rule set which created this flow."
    ::= { acctFlowEntry 25 }

acctFlowToOctets OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The count of octets flowing from source to dest address and
        being delivered to the protocol level being metered.  In the
        case of IP this would count the number of octets delivered to
        the IP level."
    ::= { acctFlowEntry 26 }

acctFlowToPDUs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The count of protocol packets flowing from source to dest
        address and being delivered to the protocol level being
        metered.  In the case of IP, for example, this would count the
        IP packets delivered to the IP protocol level."
    ::= { acctFlowEntry 27 }

acctFlowFromOctets OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The count of octets flowing from dest to source address and
        being delivered to the protocol level being metered."
    ::= { acctFlowEntry 28 }

acctFlowFromPDUs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The count of protocol packets flowing from dest to source
        address and being delivered to the protocol level being
        metered.  In the case of IP, for example, this would count the
        IP packets delivered to the IP protocol level."
    ::= { acctFlowEntry 29 }

acctFlowFirstTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The time at which this flow was first entered in the table"
    ::= { acctFlowEntry 30 }

acctFlowLastTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "The last time this flow had activity, i.e. the time of
        arrival of the last PDU belonging to this flow."
    ::= { acctFlowEntry 31 }

acctFlowSourceSubscriberID OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Subscriber ID associated with the source address for this
        flow."
    ::= { acctFlowEntry 32 }

acctFlowDestSubscriberID OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Subscriber ID associated with the dest address for this
        flow."
    ::= { acctFlowEntry 33 }

acctFlowSessionID OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Session ID for this flow.  Such an ID might be allocated
        by a network access server to distinguish a series of sessions
        between the same pair of addresses, which would otherwise
        appear to be parts of the same accounting flow."
    ::= { acctFlowEntry 34 }

acctFlowSourceClass OBJECT-TYPE
    SYNTAX  INTEGER (1..255)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Source class for this flow.  Determined by the rules, set by
         a PushRule action when this flow was entered in the table."
    ::= { acctFlowEntry 35 }

acctFlowDestClass OBJECT-TYPE
    SYNTAX  INTEGER (1..255)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Destination class for this flow.  Determined by the rules, set
         by a PushRule action when this flow was entered in the table."
    ::= { acctFlowEntry 36 }

acctFlowClass OBJECT-TYPE
    SYNTAX  INTEGER (1..255)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Class for this flow.  Determined by the rules, set by a
         PushRule action when this flow was entered in the table."
    ::= { acctFlowEntry 37 }

acctFlowSourceKind OBJECT-TYPE
    SYNTAX  INTEGER (1..255)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Source kind for this flow.  Determined by the rules, set by
         a PushRule action when this flow was entered in the table."
    ::= { acctFlowEntry 38 }

acctFlowDestKind OBJECT-TYPE
    SYNTAX  INTEGER (1..255)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Destination kind for this flow.  Determined by the rules, set
         by a PushRule action when this flow was entered in the table."
    ::= { acctFlowEntry 39 }

acctFlowKind OBJECT-TYPE
    SYNTAX  INTEGER (1..255)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Class for this flow.  Determined by the rules, set by a
         PushRule action when this flow was entered in the table."
    ::= { acctFlowEntry 40 }


--
-- The Creation Table
--

acctCreationTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AcctCreationEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "Window into the Flow Table.  Allows a collector to find all
        flows wich were created after a given time."
    ::= { acctFlowdata 2 }

acctCreationEntry OBJECT-TYPE
    SYNTAX  AcctCreationEntry
    ACCESS  not-accessible
    STATUS   mandatory
    DESCRIPTION
        "The Creation Entry for a particular flow."
    INDEX { acctCreationTime, acctCreationIndex }
    ::= { acctCreationTable 1 }

AcctCreationEntry ::= SEQUENCE {
    acctCreationTime             TimeTicks,
    acctCreationIndex            INTEGER (1..65535)
    }
acctCreationTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Earliest time after which a required flow could
        have been created."
    ::= { acctCreationEntry 1 }

acctCreationIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Index of next entry in flow table created after Creation
        Time."
    ::= { acctCreationEntry 2 }


--
-- The Activity Table
--

acctActivityTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AcctActivityEntry
    ACCESS  not-accessible
    STATUS   mandatory
    DESCRIPTION
        "Window into the Flow Table.  Allows a collector to find all
        flows wich were last used after a given time."
    ::= { acctFlowdata 3 }

acctActivityEntry OBJECT-TYPE
    SYNTAX  AcctActivityEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "The Activity Entry for a particular flow."
    INDEX { acctActivityTime, acctActivityIndex }
    ::= { acctActivityTable 1 }

AcctActivityEntry ::= SEQUENCE {
    acctActivityTime            TimeTicks,
    acctActivityIndex           INTEGER (1..65535)
    }
acctActivityTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Earliest time after which a required flow could have
        been active."
    ::= { acctActivityEntry 1 }

acctActivityIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Index of next entry in flow table active after Active Time."
    ::= { acctActivityEntry 2 }


--
-- The Activity Column Table
--

acctActivityColumnTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AcctActivityColumnEntry
    ACCESS  not-accessible
    STATUS   mandatory
    DESCRIPTION
        "Window into the Flow Table.  Allows a collector to find all
        flows wich were last used after a given time, and to retrieve
        data values for a specified attribute of each active flow."
    ::= { acctFlowdata 4 }

acctActivityColumnEntry OBJECT-TYPE
    SYNTAX  AcctActivityColumnEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "The Activity Column Entry for a particular flow."
    INDEX { acctActivityColumnAttribute, acctActivityColumnTime,
            acctActivityColumnIndex }
    ::= { acctActivityColumnTable 1 }

AcctActivityColumnEntry ::= SEQUENCE {
    acctActivityColumnAttribute   INTEGER (1..42),
    acctActivityColumnTime        TimeTicks,
    acctActivityColumnIndex       INTEGER,
    acctActivityColumnFlowData    Opaque
    }
acctActivityColumnAttribute OBJECT-TYPE
    SYNTAX  INTEGER (1..42)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Attribute for which values are required from active flows.
        Each attribute is identified by an attribute number, which
        is its offset within acctFlowEntry (above).  For example,
        SourceAdjacentAddress is attribute number 5."
    ::= { acctActivityColumnEntry 1 }
acctActivityColumnTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Earliest time after which a required flow could have
        been active."
    ::= { acctActivityColumnEntry 2 }

acctActivityColumnIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Index of next entry in flow table active after
        acctColumnTime."
    ::= { acctActivityColumnEntry 3 }

acctActivityColumnFlowData OBJECT-TYPE
    SYNTAX  Opaque
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "Collection of attribute data for flows active after
        acctColumnTime.  Within the Opaque object is a sequence of
        { flow index, attribute value } pairs, one for each active flow.
        The end of the sequence is marked by a flow index value of 0
        if there are no more rows in this column, and 1 otherwise.

        The format of objects inside acctColumnFlowData is as follows.
        All numbers are unsigned.  Numbers and strings appear with
        their high-order bytes leading.  flow-1 is a two-byte number;
        other numbers are fixed size, as specified by their SYNTAX
        in the flow table (above), i.e. one byte for acctAddressType
        and small constants, and four bytes for Counter and Timeticks.
        Octet Strings are variable-length, with the length given in a
        single leading byte."
    ::= { acctActivityColumnEntry 4 }



--
-- The Rule Table
--

-- This is an array of rule tables; the one in use is selected by
-- CurrentRuleSet.  To change the rule set the manager chooses a set
-- number which is not in use, downloads the new rule set there, then
-- writes the new set number into CurrentRuleSet.  Rule set 1 is the
-- default rule set, used by the meter on start-up.  Several rule sets
-- can be held in a meter so that the manager can change the rules 
-- easily, for example with time of day.  Note that the manager may
-- not change the default rule set, nor the rules in the current rule 
-- set!

acctRuleTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF AcctRuleEntry
    ACCESS  not-accessible
    STATUS   mandatory
    DESCRIPTION
        "The list of rules used to determine the
        granularity of accounting data."
    ::= { acctRuledata 1 }

acctRuleEntry OBJECT-TYPE
    SYNTAX  AcctRuleEntry
    ACCESS  not-accessible
    STATUS   mandatory
    DESCRIPTION
        "The rule record itself."
    INDEX { acctRuleSet, acctRuleIndex }
    ::= { acctRuleTable 1 }

AcctRuleEntry ::= SEQUENCE {
    acctRuleSet                  INTEGER,
    acctRuleIndex                INTEGER (1..65535),
    acctRuleSelector             INTEGER,       -- select attribute
    acctRuleMask                 OCTET STRING,  -- mask value
    acctRuleMatchedValue         OCTET STRING,  -- matched value
    acctRuleAction               INTEGER,       -- action to take
    acctRuleJumpIndex            INTEGER        -- where to go
    }

acctRuleSet OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Selects a table from the array of rule tables."
    ::= { acctRuleEntry 1 }

acctRuleIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "The index into the Rule table.  N.B: These values will
        often be consecutive, given the fall-through semantics of
        processing the table."
    ::= { acctRuleEntry 2 }

acctRuleSelector OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "Defines the source of the value to match.  Allowable
        selector values are described below.

        Null(0) is a special case; null rules always succeed.

        The following flow attributes may be selected (using their
        attribute numbers):
            SourceInterface(3),
            SourceAdjacentType(4),
            SourceAdjacentAddress(5),
            SourcePeerType(7),
            SourcePeerAddress(8),
            SourceTransType(10),
            SourceTransAddress(11),
            DestInterface(13),
            DestAdjacentType(14),
            DestAdjacentAddress(15),
            DestPeerType(17),
            DestPeerAddress(18),
            DestTransType(20),
            DestTransAddress(21),
            SourceSubscriberID(32),
            DestSubscriberID(33),
            SessionID(34)

        Var1(51), Var2(52), Var3(53), Var4(54) and Var5(55) select
        meter variables, each of which can hold the name (i.e.
        selector value) of an address attribute.  When one of these
        is used as a selector, its value specifies the attribute to
        be tested.  Variable values are set by an Assign action."
    ::= { acctRuleEntry 3 }

acctRuleMask OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "The initial mask used to compute the desired value, encoded
        as an OCTET STRING.  If the mask is zero the rule's test will 
        always succeed."
    ::= { acctRuleEntry 4 }

acctRuleMatchedValue OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "The resulting value to be matched for equality.
        Specifically, if the attribute chosen by the acctRuleSelector
        logically ANDed with the mask specified by the acctRuleMask
        equals the value specified in the acctRuleMatchedValue, then
        continue processing the table entry based on the action
        specified by the acctRuleAction entry.  Otherwise, proceed to
        the next entry in the rule table."
    ::= { acctRuleEntry 5 }

acctRuleAction OBJECT-TYPE
    SYNTAX  INTEGER { ignore(1), retry(2), count(3), countpkt(4),
        return(5), gosub(6), gosubact(7), assign(8), assignact(9),
        goto(10), gotoact(11), 
        pushrule(12), pushruleact(13), pushpkt(14), pushpktact(15) }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "The action to be taken if there is a match between this rule
        and the PDU being considered, or if this rule is executed
        as the result of a return, gosubact, assignact, gotoact,
        pushruleact or pushpktact action in the last rule executed.
        The meter maintains a pattern stack (i.e. a stack of attribute
        information saved by rules which have executed pushrule or
        pushpkt actions), and a return stack (i.e. a stack of return
        addresses for rule-matching subroutines).

        Ignore(1) stops rule matching for the PDU.  It will not
            be counted.
        Retry(2) terminates rule matching and indicates that the PDU
            was not matched.  The meter may try to match it again, for
            example with the source and dest keys interchanged.

        Count(3) counts this PDU in a flow which is part of the count
            table specified by acctRuleJumpIndex.  Count tables are
            tables of flows maintained internally by the meter; they
            are not visible via the MIB.  Attribute values for flows
            in a count table are taken from the pattern stack, in the
            same order as they were pushed during rule processing.
            The user should ensure that every flow in a count table
            has the same set of masks for its attribute values, i.e.
            was created by the same sequence of PushRule and/or
            PushPkt RuleActions.
        CountPkt(4) executes a PushPkt(14) action (see below), then
            a Count(3) action (see above).

        Return(5) returns from a rule-matching subroutine.  The return
            rule index is popped from the return stack and added to
            RuleJumpIndex to select a target rule.  The action for the
            target rule is executed immediately, allowing rule-matching
            subroutines to return a result.
        GoSub(6) calls a rule-matching subroutine.  RuleJumpIndex is
            used as the index of the next rule to match, and the meter
            pushes the current rule index+1 onto the return stack.
        GoSubAct(7) is the same as GoSub(6) except that execution
            of the subroutine's first rule starts with its action,
            not it's test.
        Assign(8) sets the value of a meter variable.  The variable is
            specified by acctRuleSelector and its value is set to
            RuleMatchedValue.  Assign(8) and AssignAct(9) rules should
            never perform a test; this means they should always be
            executed as the result of a return, gosubact, assignact,
            gotoact, pushruleact or pushpktact action.
        AssignAct(9) is the same as Assign(8) except that execution
            of the next rule starts with its action, not it's test.

        Goto(10) tells the meter to use RuleJumpIndex as the index of
            the next rule to match.  The pattern stack is not changed.
        GotoAct(11) is the same as Goto(10) except that execution
            of the target rule starts with its action, not it's test.

        PushRule(12) tells the meter to use RuleJumpIndex as the index
            of the next rule to match.  It also pushes the attribute
            name, mask and value from this rule onto the pattern stack.
        PushRuleAct(13) is the same as PushRule(10) except that
            execution of the target rule starts with its action, not
            it's test.
        PushPkt(14) tells the meter to use RuleJumpIndex as the index
            of the next rule to match.  It also pushes the attribute
            name and mask from this rule, together with the masked
            attribuute value from the PDU, onto the pattern stack.
            RuleMatchedValue is not used by PushPkt(14), so PushPkt(14)
            and PushPktAct(15) rules should always be executed as the
            result of a return, gosubact, assignact, gotoact, 
            pushruleact or pushpktact action.
        PushPktAct(15) is the same as PushPkt(14) except that execution
            of the target rule starts with its action, not its test."
    ::= { acctRuleEntry 6 }

acctRuleJumpIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        "An index into the Rule table.  Where to restart the search.
        Must take on one of the values allowed for acctRuleIndex."
    ::= { acctRuleEntry 7 }


END